To improve the stability and reliability of the piezoelectric micro-pump, the cause of air block phenomenon is analyzed on the structure of wheel check valve. During the movement of the bubble in the micro-channel, pressure drop occurs, the main factor which influences the bubble going through is opening height of the wheel check valve. Five groups of wheel check valves with different structures are used to test the wheel check valve opening height and air block probability. The experiment results show that reducing the wheel check valve thickness or diameter ratio can both increase the wheel check valve opening height, and decrease the air block probability. Through experiment, the optimum combination of the wheel check valve structure is obtained within the samples: as the thickness is 0.02 mm, the diameter ratio is 1.2, the wheel check valve opening height gets 252 µm, and within the given bubble volume, the air block probability is less than 2%.Keywords
This publication has 16 references indexed in Scilit:
- Adiabatic two-phase flow in rectangular microchannels with different aspect ratios: Part II – bubble behaviors and pressure drop in single bubbleInternational Journal of Heat and Mass Transfer, 2010
- MEMS-based micropumps in drug delivery and biomedical applicationsSensors and Actuators B: Chemical, 2008
- Design, modeling and fabrication of a constant flow pneumatic micropumpJournal of Micromechanics and Microengineering, 2007
- Inertial and interfacial effects on pressure drop of Taylor flow in capillariesAIChE Journal, 2005
- Micropumps—past, progress and future prospectsSensors and Actuators B: Chemical, 2005
- A polymeric piezoelectric micropump based on lamination technologyJournal of Micromechanics and Microengineering, 2004
- A fully polymeric micropump with piezoelectric actuatorSensors and Actuators B: Chemical, 2004
- Micro check valves for integration into polymeric microfluidic devicesJournal of Micromechanics and Microengineering, 2003
- A valve-less diffuser micropump for microfluidic analytical systemsSensors and Actuators B: Chemical, 2001
- The motion of long bubbles in polygonal capillaries. Part 2. Drag, fluid pressure and fluid flowJournal of Fluid Mechanics, 1995