Efficacy of High-Pressure Balloon for the Treatment of Arteriovenous Fistula Stenosis: A Meta-Analysis
Authors:
- 2 December 2021
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 29 (4) , 627-636
Abstract
Objective: The objective of the present study was to compare the effectiveness of high-pressure balloon (HPB) versus conventional balloon (CB) angioplasty in treating arteriovenous fistula (AVF) stenosis. Materials and Methods: A meta-analysis was conducted using data acquired from PubMed, EMBASE, the Cochrane Library, SinoMed, CNKI, WanFang, and VIP databases from the time the databases were established to December 2020. All analyses included in the studies comprised the subgroups of HPB and CB. The patency rates of AVF were compared between 2 groups at 3, 6, and 12 months after operation. Results: Seven studies comprising 364 patients were included in the meta-analyses. The pooled results revealed that restenosis rate of AVFs treated with HPB was significantly lower than that of AVFs treated with CB at 3 months (odds ratio [OR] = 0.32, 95% confidence interval [CI] = 0.16 to 0.61, p<0.001) and 6 months after operation (OR= 0.29, 95% CI = 0.11 to 0.79, p = 0.01). In addition, the technical success rate of HPB groups was higher (OR = 0.13, 95% CI = 0.05 to 0.36, p<0.001). However, no significant difference was observed between HPB and CB groups at 12 months after operation (OR = 0.68, 95% CI = 0.30 to 1.52, p = 0.35). No significant publication bias was observed in the analyses. Conclusion: High-pressure balloon is a potential option for the treatment of AVF stenosis, with a lower 3- and 6-month restenosis rate than CB. However, 12-month patency rate of HPB was not superior to CB. Therefore, further studies should be conducted to investigate the mechanisms of restenosis after angioplasty.Keywords
All Related Versions
This publication has 13 references indexed in Scilit:
- Clinical Experience with Very High-Pressure Dilatation for Resistant Coronary LesionsCardiovascular Revascularization Medicine, 2019
- Hemodialysis Arteriovenous Fistula and Graft Stenoses: Randomized Trial Comparing Drug-eluting Balloon Angioplasty with Conventional AngioplastyRadiology, 2018
- When everything else fails: High-pressure balloon for undilatable lesionsCardiovascular Revascularization Medicine, 2018
- Comparing the 12-month patency of low- versus high-pressure dilation in failing arteriovenous fistulae: A prospective multicenter trial (YOROI study)The Journal of Vascular Access, 2018
- Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloonEuroIntervention, 2016
- Comparison of Cutting Balloon Angioplasty and Percutaneous Balloon Angioplasty of Arteriovenous Fistula Stenosis: A Meta‐Analysis and Systematic Review of Randomized Clinical TrialsJournal of Interventional Cardiology, 2015
- Randomized Clinical Trial of Cutting Balloon Angioplasty versus High-Pressure Balloon Angioplasty in Hemodialysis Arteriovenous Fistula Stenoses Resistant to Conventional Balloon AngioplastyJournal of Vascular and Interventional Radiology, 2014
- Prospective Study of Balloon Inflation Pressures and Other Technical Aspects of Hemodialysis Access AngioplastyJournal of Vascular and Interventional Radiology, 2005
- Vascular restenosis – striving for therapyExpert Opinion on Pharmacotherapy, 2004
- Highly increased cell proliferation activity in the restenotic hemodialysis vascular access after percutaneous transluminal angioplasty: implication in prevention of restenosisAmerican Journal of Kidney Diseases, 2004