Using septum‐capped vials with continuous‐flow isotope ratio mass spectrometric analysis of atmospheric CO 2 for Keeling plot applications
Authors:
- 23 May 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (12) , 952-956
Abstract
Recent advances in continuous‐flow isotope ratio mass spectrometry have made possible automated analysis of δ 13 C and δ 18 O in CO 2 in air from 10‐mL septum‐capped vials. With the potential to collect, transport, and analyze a large number of air samples using these small inexpensive vials, the opportunity exists for routine and statistically robust sampling of CO 2 for Keeling plot applications. With the above‐mentioned objectives in mind, we measured the precision of carbon and oxygen stable isotope ratios in the CO 2 of air within septum‐capped vials using a Finnigan MAT Delta plus XL continuous‐flow isotope ratio mass spectrometer (CF‐IRMS) interfaced to a GasBench II. The standard deviation of 45 δ 13 C PDB and δ 18 O VSMOW measurements from five vials filled with identical tank air was 0.08‰ and 0.14‰, respectively. This translated into a measurement precision (standard error; SE) of 0.01‰ δ 13 C PDB and 0.02‰ δ 18 O VSMOW . This precision was similar to that obtained with the tank air introduced directly into the GasBench II by bypassing the vials/autosampler (also with a SE = 0.01‰ for both δ 13 C PDB and δ 18 O VSMOW ), suggesting minimal vial‐related effects with no storage time at ambient pressure and CO 2 concentration. Further, puncturing the butyl rubber septa during filling just prior to analysis did not affect the precision (SE = 0.01‰ for both δ 13 C PDB and δ 18 O VSMOW , n = 45). After nine days of storage in vials with unpunctured septa, neither δ 13 C PDB nor δ 18 O VSMOW changed significantly, although the precision decreased to ∼0.04‰ for both δ 13 C PDB and δ 18 O VSMOW . A greater decrease in precision was observed for vials with punctured septa (from 0.01‰ to 0.10‰ SE for both δ 13 C PDB and δ 18 O VSMOW ). Further, whereas vials with punctured septa showed no change in δ 18 O VSMOW , δ 13 C PDB decreased by 0.07‰/day ( r 2 = 0.96). In practice, such storage‐related effects could be accounted for based on concurrent changes in reference standards. These results suggest that air may be collected and stored in 10‐mL septum‐capped vials and analyzed in an automated fashion with the Gas Bench II/Delta plus with sufficient precision for Keeling plot applications. Further, a relatively high sample throughput of about 4 vials per hour or about 100 vials or 2000 injections per day offers the potential for high precision with large sample sizes. Higher throughput should permit experimental advances that were not possible before. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 6 references indexed in Scilit:
- Sample vial influences on the accuracy and precision of carbon and oxygen isotope ratio analysis in continuous flow mass spectrometric applicationsRapid Communications in Mass Spectrometry, 2000
- Carbon and oxygen isotope ratios of ecosystem respiration along an Oregon conifer transect: preliminary observations based on small-flask samplingTree Physiology, 1998
- Vegetation Effects on the Isotopic Composition of Atmospheric CO2 at Local and Regional Scales: Theoretical Aspects and a Comparison Between Rain Forest in Amazonia and a Boreal Forest in SiberiaAustralian Journal of Plant Physiology, 1996
- Fluxes of CO2 and water between terrestrial vegetation and the atmosphere estimated from isotope measurementsNature, 1996
- Partitioning of ocean and land uptake of CO2 as inferred by δ13C measurements from the NOAA Climate Monitoring and Diagnostics Laboratory Global Air Sampling NetworkJournal of Geophysical Research: Atmospheres, 1995
- The concentration and isotopic abundances of atmospheric carbon dioxide in rural areasGeochimica et Cosmochimica Acta, 1958