Assessment of the Pulmonary Volume Pulse in Idiopathic Pulmonary Arterial Hypertension by Means of Electrical Impedance Tomography
Authors:
- Henk J. SmitHSHenk J. Smit
- Anton Vonk-NoordegraafAVAnton Vonk-Noordegraaf
- Anco BoonstraABAnco Boonstra
- Peter M. de VriesPVPeter M. de Vries
- Pieter E. PostmusPPPieter E. Postmus
- 1 September 2006
- journal article
- research article
- Published by S. Karger AG in Respiration
- Vol. 73 (5) , 597-602
Abstract
Background: Electrical impedance tomography (EIT) is a non-invasive imaging technique which can be used to measure the blood volume changes in the pulmonary vascular bed during the cardiac cycle. Study Objectives: This study was performed to evaluate the differences in the EIT signal of the pulmonary vascular bed between healthy subjects and patients with idiopathic pulmonary arterial hypertension (IPAH), who are known to have a remodelled pulmonary vascular bed. Patients and Methods: Twenty-one patients (17 females, 4 males) with IPAH and 30 healthy controls (5 females, 25 males) were measured. EIT measurements were performed in duplicate, on the same day as right heart catheterization to obtain haemodynamic data. The maximal impedance change during systole (Δ Zsys) was used as a measure of the pulmonary volume pulse and expressed in arbitrary units (AU). Total lung capacity, spirometric values and diffusion capacity for carbon monoxide were measured as well. Results: Mean Δ Zsys was 215 ± 58 × 10–2 AU (95% CI 193 × 10–2 to 236 × 10–2) in the healthy subjects and 78 ± 27 × 10–2 AU (95% CI 66 × 10–2 to 91 × 10–2) in the IPAH patient group (p < 0.0001). No significant correlation was found between Δ Zsys and any of the haemodynamic or lung function data. Conclusion: The impedance pulsation of the pulmonary vascular bed is reduced in IPAH in comparison with controls, indicating a reduced volume pulse. This might represent the reduced cross section area, as well as the reduced compliance and number of the pulmonary vessels in these patients.Keywords
This publication has 24 references indexed in Scilit:
- Clinical classification of pulmonary hypertensionJACC, 2004
- Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice?Physiological Measurement, 2003
- Diffusion capacity and haemodynamics in primary and chronic thromboembolic pulmonary hypertensionEuropean Respiratory Journal, 2000
- A real-time electrical impedance tomography system for clinical use-design and preliminary resultsIEEE Transactions on Biomedical Engineering, 1995
- Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT imagesClinical Physics and Physiological Measurement, 1992
- An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusionClinical Physics and Physiological Measurement, 1988
- Methods of cardiac gating applied potential tomographyClinical Physics and Physiological Measurement, 1988
- The Sheffield data collection systemClinical Physics and Physiological Measurement, 1987
- Localisation of cardiac related impedance changes in the thoraxClinical Physics and Physiological Measurement, 1987
- Theoretical limits to sensitivity and resolution in impedance imagingClinical Physics and Physiological Measurement, 1987