Abstract
Tactile sensors mounted on grippers play a crucial role in enabling robots to grasp a variety of objects accurately. In this paper, we propose a hybrid magnetic and self-capacitance proximity and tactile sensor that combines a self-capacitance proximity and tactile sensor with a magnetic tactile sensor. The self-capacitance proximity and tactile sensor enables both non-contact measurements and one-axis contact pressure sensing, while the magnetic sensor provides three-axis pressure measurements. To address the influence of an object’s magnetism on magnetic sensing, corrections are applied using contact information from the self-capacitance sensor. The prototype sensor measures 20 × 20 mm with a thickness of approximately 8.5 mm and operates at a sampling rate of approximately 70 Hz. In experiments, grounded conductors were detected at distances of approximately 40 mm and dielectric objects (acrylic) at approximately 20 mm in the non-contact state. The sensor measured Z-axis forces to 10 N and X-Y forces to ±3 N. Experimental results demonstrate that the proposed sensor can detect objects in close proximity and measure three-axis contact forces, even for magnetic objects. Thus, the proposed sensor is a promising tactile sensing solution for robotic grippers.
Funding Information
  • Japan Society for the Promotion of Science (JSPS) Kakenhi (25K07688)

This publication has 20 references indexed in Scilit: