Improvements in parallel imaging accelerated functional MRI using multiecho echo-planar imaging
Open Access
- 29 March 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (4) , 959-969
Abstract
Multiecho echo‐planar imaging (EPI) was implemented for blood‐oxygenation‐level‐dependent functional MRI at 1.5 T and compared to single‐echo EPI with and without parallel imaging acceleration. A time‐normalized breath‐hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1–3. Experiments were conducted in five human subjects, each scanned in three sessions. Across all reduction factors, both signal‐to‐fluctuation‐noise ratio and the total number of activated voxels were significantly lower using a single‐echo EPI pulse sequence compared with the multiecho approach. Signal‐to‐fluctuation‐noise ratio and total number of activated voxels were also considerably reduced for nonaccelerated conventional single‐echo EPI when compared to three‐echo measurements with R = 2. Parallel imaging accelerated multiecho EPI reduced geometric distortions and signal dropout, while it increased blood‐oxygenation‐level‐dependent signal sensitivity all over the brain, particularly in regions with short underlying T *2. Thus, the presented method showed multiple advantages over conventional single‐echo EPI for standard blood‐oxygenation‐level‐dependent functional MRI experiments. Magn Reson Med 63:959–969, 2010.Keywords
This publication has 32 references indexed in Scilit:
- Theoretical optimization of multi-echo fMRI data acquisitionPhysics in Medicine & Biology, 2007
- Potential and feasibility of parallel MRI at high fieldNMR in Biomedicine, 2006
- BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: Parallel‐acquired inhomogeneity‐desensitized fMRIMagnetic Resonance in Medicine, 2006
- Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRINeuroImage, 2005
- Application of sensitivity‐encoded echo‐planar imaging for blood oxygen level‐dependent functional brain imaging †Magnetic Resonance in Medicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Physiological noise in oxygenation‐sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- Color-Word Matching Stroop Task: Separating Interference and Response ConflictNeuroImage, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990