Dimensional reductions of a cardiac model for effective validation and calibration
- 8 December 2013
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 13 (4) , 897-914
Abstract
Complex 3D beating heart models are now available, but their complexity makes calibration and validation very difficult tasks. We thus propose a systematic approach of deriving simplified reduced-dimensional models, in “0D”—typically, to represent a cardiac cavity, or several coupled cavities—and in “1D”—to model elongated structures such as muscle samples or myocytes. We apply this approach with an earlier-proposed 3D cardiac model designed to capture length-dependence effects in contraction, which we here complement by an additional modeling component devised to represent length-dependent relaxation. We then present experimental data produced with rat papillary muscle samples when varying preload and afterload conditions, and we achieve some detailed validations of the 1D model with these data, including for the length-dependence effects that are accurately captured. Finally, when running simulations of the 0D model pre-calibrated with the 1D model parameters, we obtain pressure–volume indicators of the left ventricle in good agreement with some important features of cardiac physiology, including the so-called Frank–Starling mechanism, the End-Systolic Pressure–Volume Relationship, as well as varying elastance properties. This integrated multi-dimensional modeling approach thus sheds new light on the relations between the phenomena observed at different scales and at the local versus organ levels.Keywords
This publication has 65 references indexed in Scilit:
- Estimation of tissue contractility from cardiac cine-MRI using a biomechanical heart modelBiomechanics and Modeling in Mechanobiology, 2011
- Impact of myocyte strain on cardiac myofilament activationPflügers Archiv - European Journal of Physiology, 2011
- The Finite Element Analysis of Shells - Fundamentals2011
- Modeling the relation between cardiac pump function and myofiber mechanicsJournal of Biomechanics, 2003
- A Biomechanical Model of Muscle Contraction2001
- Length–Tension Relationships of Sub-epicardial and Sub-endocardial Single Ventricular Myocytes from Rat and Ferret HeartsJournal of Molecular and Cellular Cardiology, 2000
- Active force in rabbit ventricular myocytesJournal of Biomechanics, 1995
- Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wallBiophysical Journal, 1991
- Dual control of relaxation. Its role in the ventricular function in the mammalian heart.Circulation Research, 1980
- Onset of Mechanical Activation of Mammalian Heart Muscle in Calcium- and Strontium-Containing SolutionsCirculation Research, 1974