Single-Lung Ventilation with a Cuffed Endotracheal Tube in a Child with a Left Mainstem Bronchus Disruption
Authors:
- Won-Kyoung KwonWKWon-Kyoung Kwon
- Kyoung-Ok KimKKKyoung-Ok Kim
- Hee-Soo KimHKHee-Soo Kim
- Chong-Sung KimCKChong-Sung Kim
- 1 March 2003
- journal article
- case report
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (3) , 696-697
Abstract
We report a case of management of ventilation during operative repair of a traumatic left mainstem bronchial disruption in a pediatric patient. With the use of a conventional cuffed endotracheal tube, with the cuff partially in the right mainstem bronchus and partially in the trachea, we successfully managed the case with single-lung ventilation.Keywords
This publication has 7 references indexed in Scilit:
- Methods of lung separationCurrent Opinion in Anaesthesiology, 2002
- Thoracic surgery in childrenCurrent Opinion in Anaesthesiology, 2001
- Methods for Single-Lung Ventilation in Pediatric PatientsAnesthesia & Analgesia, 1999
- Thoracic AnesthesiaSeminars in Respiratory and Critical Care Medicine, 1999
- Bronchial Injury During Lung Isolation in a Pediatric PatientAnesthesia & Analgesia, 1998
- Single-lung Ventilation in Pediatric PatientsAnesthesiology, 1996
- New Endotracheal Tube (Univent Tube®) for Selective Blockade of One LungAnesthesiology, 1985