A 3-D finite element analysis of the effect of dental implant thread angle on stress distribution in the surrounding bone
Open Access
- 29 May 2022
- journal article
- research article
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 16 (1) , 53-61
Abstract
Background. This study aimed to evaluate the effect of an increase in fixture thread face angle on the amount and distribution of stresses in the surrounding bone of implants with four different thread shapes by three-dimensional finite element analysis. Methods. Eight different fixture designs, with v-shaped, buttress, reverse buttress, and trapezoid threads, and two face angles of 20 and 35 degrees, were modeled using a software program. Each model was affected by two static forces with different values and angles (200-N axial 0° force and 100-N 45° oblique force) to compare the distribution of stress in different fixture designs. Results. The maximum von Mises stress was detected in v-shaped threads. An increase in the angle of the threads to 35° significantly decreased maximum von Mises stress in cortical bone in v-shaped and reverse buttress threads; however, the von Mises stress in the trapezoid and buttress threads increased with an increase in the thread angle. Conclusion. Under the limitations of this study, although the shape of the thread and thread surface angle does not have a definite role in stress distribution in the bone surrounding the implant, they are effective in the amount and type of stress induced in the bone supporting the implant.Keywords
This publication has 17 references indexed in Scilit:
- Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implantsBiotechnology & Biotechnological Equipment, 2015
- Preimplant Prosthodontics2015
- The influence of thread geometry on implant osseointegration under immediate loading: a literature reviewThe Journal of Advanced Prosthodontics, 2014
- Effects of implant threads on the contact area and stress distribution of marginal boneJournal of Dental Sciences, 2010
- The effect of thread pattern upon implant osseointegrationClinical Oral Implants Research, 2010
- The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysisClinical Oral Investigations, 2009
- A descriptive study on retrieved non‐threaded and threaded implant designsClinical Oral Implants Research, 2005
- Effects of Implant Thread Geometry on Percentage of Osseointegration and Resistance to Reverse Torque in the Tibia of RabbitsJournal of Periodontology, 2004
- Finite element analysis of four thread‐form configurations in a stepped screw implantJournal of Oral Rehabilitation, 2004
- Preliminary Evaluation of a New Dental Implant Design in Canine ModelsImplant Dentistry, 2000