RETRACTED: Comparison of three peripherally inserted central catheters: pilot study
Author:
- 8 January 2009
- journal article
- retracted article
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 18 (1) , 8-16
Abstract
Peripherally-inserted central catheters (PICCS) are non-tunnelled, central catheters inserted through a peripheral vein of the arm. They are 50–60 cm long and are usually made of either silicone or second-third generation polyurethane. PICCs can be used for prolonged, continuous or intermittent infusion therapies (up to 3 months) both in hospitalized patients and in patients treated as outpatients, in a hospice, or at home. When establishing a vascular service it is key to select a PICC that meets the requirements of safety, cost-effectiveness, high resistance (ability to take increasing fluid volumes with high pressure devices) and durability, and low complications rate. The complications and dwell times of three different PICCs were studied: coated polyurethane, valved silicone and powerinjectable. The study was conducted at the chemotherapy suite at the author’s hospital with the aim of selecting the right PICC based on low incidence of complications, resistance and enhanced dwell time. Results show a low incidence of complications and long dwell time among patients with the power-injectable PICC. Furthermore, this study demonstrated a reduction on the rate of occlusion and rupture with power-injectable PICCs, which makes them safer to use for administration of chemotherapy and other vesicant agents, as well as for the management of patients in critical care.Keywords
This publication has 14 references indexed in Scilit:
- Vascular Access in Oncology PatientsCA: A Cancer Journal for Clinicians, 2008
- EDITORIALJournal of Infusion Nursing, 2006
- Preventing Complications of Central Venous CatheterizationNew England Journal of Medicine, 2003
- Skin Flora and InfectionJournal of Infusion Nursing, 2003
- The Use of Polyurethane PICCs: An Alternative to Other Catheter MaterialsJournal of Vascular Access Devices, 2002
- The epic Project: Developing National Evidence-based Guidelines for Preventing Healthcare associated InfectionsJournal of Hospital Infection, 2001
- The experiences of patients and nurses with a nurse-led peripherally inserted central venous catheter line serviceEuropean Journal of Oncology Nursing, 2000
- Current treatment options for catheter-related thrombosisJournal of Vascular Access Devices, 2000
- Prevention of central venous catheter-related infectionJournal of Hospital Infection, 1998
- Tip Location of Peripherally Inserted Central CathetersJournal of Vascular Access Devices, 1998