Influence of Different Soft Liners on Stress Distribution in Peri-Implant Bone Tissue During Healing Period. A 3D Finite Element Analysis
- 1 October 2013
- journal article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 39 (5) , 575-581
Abstract
The aim of this study was to evaluate the stress distribution in the bone adjacent to submerged implants during masticatory function in conventional complete dentures with different soft liners through finite element analysis. Three-dimensional models of a severely resorbed mandible with 2 and 4 submerged implants in the anterior region were created and divided into the following situations: (1) conventional complete dentures (control group); and conventional complete dentures with different soft liner materials, (2) Coe-Comfort, (3) Softliner, and (4) Molteno Hard. The models were exported to mechanical simulation software and 2 simulations were done with the load in the inferior right canine (35 N) and the inferior right first molar (50 N). The data were qualitatively evaluated using the maximum principal stress and microstrain values given by the software. The use of soft liners provides decreased levels of stress and microstrains in peri-implant bone when the load was applied to canine teeth. Considering all of the values obtained in this study, the use of softer materials is the most suitable for use during the period of osseointegration.Keywords
This publication has 25 references indexed in Scilit:
- Patients' Expectations Before and Evaluation After Dental Implant TherapyClinical Implant Dentistry and Related Research, 2011
- Force and Movement of Non-Osseointegrated Implants: An In Vitro StudyJournal of Oral Implantology, 2009
- Implant–Bone Interface Stress Distribution in Immediately Loaded Implants of Different Diameters: A Three‐Dimensional Finite Element AnalysisJournal of Prosthodontics, 2009
- Impact of implant support for mandibular dentures on satisfaction, oral and general health‐related quality of life: a meta‐analysis of randomized‐controlled trialsClinical Oral Implants Research, 2009
- Immediate loading of definitive implants in the edentulous mandible using a fixed provisional prosthesis: The denture conversion techniqueJournal of Oral and Maxillofacial Surgery, 2004
- Critical review of immediate implant loadingClinical Oral Implants Research, 2003
- Immediate Loading of Titanium Plasma‐Sprayed Implants: An Histologic Analysis in MonkeysJournal of Periodontology, 1998
- Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literatureJournal of Biomedical Materials Research, 1998
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981