Patient-specific deep learning model to enhance 4D-CBCT image for radiomics analysis
- 1 April 2022
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (8) , 085003
Abstract
Objective. 4D-CBCT provides phase-resolved images valuable for radiomics analysis for outcome prediction throughout treatment courses. However, 4D-CBCT suffers from streak artifacts caused by under-sampling, which severely degrades the accuracy of radiomic features. Previously we developed group-patient-trained deep learning methods to enhance the 4D-CBCT quality for radiomics analysis, which was not optimized for individual patients. In this study, a patient-specific model was developed to further improve the accuracy of 4D-CBCT based radiomics analysis for individual patients. Approach. This patient-specific model was trained with intra-patient data. Specifically, patient planning 4D-CT was augmented through image translation, rotation, and deformation to generate 305 CT volumes from 10 volumes to simulate possible patient positions during the onboard image acquisition. 72 projections were simulated from 4D-CT for each phase and were used to reconstruct 4D-CBCT using FDK back-projection algorithm. The patient-specific model was trained using these 305 paired sets of patient-specific 4D-CT and 4D-CBCT data to enhance the 4D-CBCT image to match with 4D-CT images as ground truth. For model testing, 4D-CBCT were simulated from a separate set of 4D-CT scan images acquired from the same patient and were then enhanced by this patient-specific model. Radiomics features were then extracted from the testing 4D-CT, 4D-CBCT, and enhanced 4D-CBCT image sets for comparison. The patient-specific model was tested using 4 lung-SBRT patients’ data and compared with the performance of the group-based model. The impact of model dimensionality, region of interest (ROI) selection, and loss function on the model accuracy was also investigated. Main results. Compared with a group-based model, the patient-specific training model further improved the accuracy of radiomic features, especially for features with large errors in the group-based model. For example, the 3D whole-body and ROI loss-based patient-specific model reduces the errors of the first-order median feature by 83.67%, the wavelet LLL feature maximum by 91.98%, and the wavelet HLL skewness feature by 15.0% on average for the four patients tested. In addition, the patient-specific models with different dimensionality (2D versus 3D) or loss functions (L1 versus L1 + VGG + GAN) achieved comparable results for improving the radiomics accuracy. Using whole-body or whole-body+ROI L1 loss for the model achieved better results than using the ROI L1 loss alone as the loss function. Significance. This study demonstrated that the patient-specific model is more effective than the group-based model on improving the accuracy of the 4D-CBCT radiomic features analysis, which could potentially improve the precision for outcome prediction in radiotherapy.Keywords
Funding Information
- National Institutes of Health (R01- EB028324)
This publication has 22 references indexed in Scilit:
- CT-based radiomic analysis of stereotactic body radiation therapy patients with lung cancerRadiotherapy and Oncology, 2016
- Radiomics: Images Are More than Pictures, They Are DataRadiology, 2016
- Can radiomics features be reproducibly measured from CBCT images for patients with non‐small cell lung cancer?Medical Physics, 2015
- Machine Learning methods for Quantitative Radiomic BiomarkersScientific Reports, 2015
- A radiomics model from joint FDG-PET and MRI texture features for the prediction of lung metastases in soft-tissue sarcomas of the extremitiesPhysics in Medicine & Biology, 2015
- A limited‐angle intrafraction verification (LIVE) system for radiation therapyMedical Physics, 2014
- Tumour heterogeneity in non-small cell lung carcinoma assessed by CT texture analysis: a potential marker of survivalEuropean Radiology, 2011
- On‐the‐fly motion‐compensated cone‐beam CT using an a priori model of the respiratory motionMedical Physics, 2009
- An accurate iterative reconstruction algorithm for sparse objects: application to 3D blood vessel reconstruction from a limited number of projectionsPhysics in Medicine & Biology, 2002
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984