A Soft Robot for Peripheral Lung Cancer Diagnosis and Therapy
- 1 August 2022
- journal article
- research article
- Published by SAGE Publications in Soft Robotics
- Vol. 9 (4) , 754-766
Abstract
Lung cancer is one of the deadliest forms of cancers and is often diagnosed by performing biopsies with the use of a bronchoscope. However, this diagnostic procedure is limited in ability to explore deep into the periphery of the lung where cancer can remain undetected. In this study, we present design, modeling, fabrication, and testing of a one degree of freedom soft robot with integrated diagnostic and interventional capabilities as well as vision sensing. The robot can be deployed through the working channel of commercial bronchoscopes or used as a stand-alone system as it integrates a micro camera to provide vision sensing and controls to the periphery of the lung. The small diameter (2.4 mm) of the device allows navigation in branches deeper in the lung, where current devices have limited reachability. We have performed mechanical characterizations of the robotic platform, including blocked force, maximum bending angle, maximum angular velocity, and workspace, and assessed its performance in in vitro and ex vivo experiments. We have developed a computer vision algorithm, and validated it in in vitro conditions, to autonomously align the robot to a selected branch of the lung and aid the clinician (by means of a graphical user interface) during navigation tasks and to perform robot-assisted stabilization in front of a lesion, with automated tracking and alignment.Keywords
This publication has 40 references indexed in Scilit:
- Snap-on robotic wrist module for enhanced dexterity in endoscopic surgery2016
- Complication rates of CT-guided transthoracic lung biopsy: meta-analysisEuropean Radiology, 2016
- Continuum Robots for Medical Applications: A SurveyIEEE Transactions on Robotics, 2015
- Design, fabrication and control of soft robotsNature, 2015
- Modeling of Soft Fiber-Reinforced Bending ActuatorsIEEE Transactions on Robotics, 2015
- Development of Flexible Bronchoscope Device Using Soft Actuator2015
- Soft Robotics Technologies to Address Shortcomings in Today's Minimally Invasive Surgery: The STIFF-FLOP ApproachSoft Robotics, 2014
- A Telerobotic System for Transnasal SurgeryIEEE/ASME Transactions on Mechatronics, 2013
- Establishing the Diagnosis of Lung CancerChest, 2013
- Some Forms of the Strain Energy Function for RubberRubber Chemistry and Technology, 1993