Evaluation of a New Simplified Inertial Sensor Method against Electrogoniometer for Measuring Wrist Motion in Occupational Studies
Open Access
Abstract
Wrist velocity is an important risk factor for work-related musculoskeletal disorders in the elbow/hand, which is also difficult to assess by observation or self-reports. This study aimed to evaluate a new convenient and low-cost inertial measurement unit (IMU)-based method using gyroscope signals against an electrogoniometer for measuring wrist flexion velocity. Twelve participants performed standard wrist movements and simulated work tasks while equipped with both systems. Two computational algorithms for the IMU-based system, i.e., IMUnorm and IMUflex, were used. For wrist flexion/extension, the mean absolute errors (MAEs) of median wrist flexion velocity compared to the goniometer were norm and flex. During wrist deviation and pronation/supination, all methods showed errors, where the IMUnorm method had the largest overestimations. For simulated work tasks, the IMUflex method had small bias and better accuracy than the IMUnorm method compared to the goniometer, with the MAEs of median wrist flexion velocity flex method is preferred. Future studies need to examine algorithms to further improve the accuracy of the IMU-based method in tasks of larger variations, as well as easy calibration procedures.Keywords
Funding Information
- Forskningsrådet för hälsa, arbetsliv och välfärd (2017-01209)
This publication has 39 references indexed in Scilit:
- Performance evaluation of a wearable inertial motion capture system for capturing physical exposures during manual material handling tasksErgonomics, 2013
- Precision of measurements of physical workload during standardized manual handling part III: Goniometry of the wristsJournal of Electromyography and Kinesiology, 2009
- Associations between work-related factors and the carpal tunnel syndrome—a systematic reviewScandinavian Journal of Work, Environment & Health, 2009
- Quantifying repetitive hand activityfor epidemiological research on musculoskeletal disorders – part I: individual exposure assessmentErgonomics, 2006
- Measurements of wrist and forearm positions and movements: effect of, and compensation for, goniometer crosstalkJournal of Electromyography and Kinesiology, 2004
- Questionnaire versus direct technical measurements in assessing postures and movements of the head, upper back, arms and handsScandinavian Journal of Work, Environment & Health, 2001
- Hand and arm injuries associated with repetitive manual work in industry: a review of disorders, risk factors and preventive measuresErgonomics, 1999
- Practical Operation of a Biaxial Goniometer at the Wrist JointHuman Factors: The Journal of the Human Factors and Ergonomics Society, 1997
- Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive workJournal of Electromyography and Kinesiology, 1996
- Rapid Communication Industrial wrist motions and incidence of hand/wrist cumulative trauma disordersErgonomics, 1994