Larger operating rooms have better air quality than smaller rooms in primary total knee arthroplasty
Authors:
- 26 April 2023
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (10) , 6335-6338
Abstract
Introduction Operating room air quality can be affected by several factors including temperature, humidity, and airborne particle burden. Our study examines the role of operating room (OR) size on air quality and airborne particle (ABP) count in primary total knee arthroplasty (TKA). Materials and methods We analyzed all primary, elective TKAs performed within two ORs measuring 278 sq ft. (small) and 501 sq ft. (large) at a single academic institution in the United States from April 2019 to June 2020. Intraoperative measurements of temperature, humidity, and ABP count were recorded. p values were calculated using t test for continuous variables and chi-square for categorical values. Results 91 primary TKA cases were included in the study, with 21 (23.1%) in the small OR and 70 (76.9%) in the large OR. Between-groups comparisons revealed significant differences in relative humidity (small OR 38.5% ± 7.24% vs. large OR 44.4% ± 8.01%, p = 0.002). Significant percent decreases in ABP rates for particles measuring 2.5 μm (− 43.9%, p = 0.007) and 5.0 μm (− 69.0%, p = 0.0024) were found in the large OR. Total time spent in the OR was not significantly different between the two groups (small OR 153.09 ± 22.3 vs. large OR 173 ± 44.6, p = 0.05). Conclusions Although total time spent in the room did not differ between the large and small OR, there were significant differences in humidity and ABP rates for particles measuring 2.5 μm and 5.0 μm, suggesting the filtration system encounters less particle burden in larger rooms. Larger studies are required to determine the impact this may have on OR sterility and infection rates.Keywords
This publication has 12 references indexed in Scilit:
- Rates of Total Joint Replacement in the United States: Future Projections to 2020–2040 Using the National Inpatient SampleThe Journal of Rheumatology, 2019
- Airborne particle dispersion to an operating room environment during sliding and hinged door openingJournal of Infection and Public Health, 2018
- Door openings in the operating room are associated with increased environmental contaminationAmerican Journal of Infection Control, 2018
- Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflowJournal of Hospital Infection, 2018
- Assessment of operating room airflow using air particle counts and direct observation of door openingsAmerican Journal of Infection Control, 2017
- Preventing surgical-site infections: Measures other than antibioticsOrthopaedics & Traumatology: Surgery & Research, 2015
- Traffic flow in the operating room: An explorative and descriptive study on air quality during orthopedic trauma implant surgeryAmerican Journal of Infection Control, 2012
- Ultraviolet Lighting During Orthopaedic Surgery and the Rate of InfectionJournal of Bone and Joint Surgery, 2007
- Movement of personnel and wound contaminationAORN Journal, 1983
- Airborne contamination of wounds in joint replacement operations: the relationship to sepsis ratesJournal of Hospital Infection, 1983