First Experience With the ICD 16.5 Mini-Scleral Lens for Optic and Therapeutic Purposes
Authors:
- Virginie MadariagaVMVirginie Madariaga
- Benoît LepageBLBenoît Lepage
- Marie MalecazeMMMarie Malecaze
- Pierre FourniéPFPierre Fournié
- Vincent SolerVSVincent Soler
- Stéphane GaliacySGStéphane Galiacy
- René MélyRMRené Mély
- Myriam CassagneMCMyriam Cassagne
- François MalecazeFMFrançois Malecaze
- 1 January 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 44 (1) , 44-49
Abstract
Objectives: To evaluate the success rate, efficacy, and safety of the ICD 16.5 mini-scleral gas permeable (GP) contact lens. Methods: This prospective study included referred consecutive patients with irregular corneas and severe ocular surface disease (OSD) in treatment failure. All patients were fitted with the ICD 16.5 mini-scleral GP lens. Even though we had some limited experience with scleral lenses, it was our first experience with the ICD 16.5 mini-scleral GP lens. Efficacy was assessed by comparing best-corrected visual acuity (BCVA) with the mini-scleral lens to baseline BCVA. A subjective visual functioning questionnaire (comfort score, visual quality score, handling rating, and wearing time) was administered in a face-to-face structured interview. Results: Thirty-nine eyes of 23 patients with a mean age of 43±16 years were included. Fitting indications were keratoconus (46%), post-penetrating keratoplasty (21%), other irregular astigmatism (15%), and severe OSD (18%). Twenty-five eyes (64%) were successfully fitted with an 18-month follow-up. The mini-scleral GP lens BCVA was 0.16 logarithm of the minimum angle of resolution (logMAR; 20/25) versus a baseline BCVA of 0.44 logMAR (20/63; P<0.001). Comfort and visual quality scores were 8.5/10 and 7.5/10, respectively. No complications were detected in 96% of the eyes (95% confidence interval, 76.1%–99.4%). One eye experienced corneal graft swelling. Conclusions: The present findings suggest that the ICD 16.5 mini-scleral GP lens is an effective and safe alternative for managing challenging corneas in a therapeutic impasse.Keywords
This publication has 25 references indexed in Scilit:
- Polymicrobial and microsporidial keratitis in a patient using Boston scleral contact lens for Sjogren's syndrome and ocular cicatricial pemphigoidContact Lens and Anterior Eye, 2013
- Fluid filled scleral contact lens in pediatric patients: Challenges and outcomeContact Lens and Anterior Eye, 2012
- Fluid-Filled Scleral Contact Lenses in Vernal KeratoconjunctivitisEye & Contact Lens: Science & Clinical Practice, 2012
- Current applications and efficacy of scleral contact lenses — a retrospective studyJournal of Optometry, 2010
- Scleral Lenses in the Management of KeratoconusEye & Contact Lens: Science & Clinical Practice, 2010
- The Value-Based Medicine Comparative Effectiveness and Cost-Effectiveness of Penetrating Keratoplasty for KeratoconusCornea, 2008
- Scleral Contact LensesCornea, 2005
- Medical Applications of Scleral Contact LensesCornea, 1995
- Gas-to-Gas oxygen permeability measurements on RGP and silicone rubber lens materialsInternational Contact Lens Clinic, 1991
- Gas permeable haptic lensesJournal of The British Contact Lens Association, 1983