A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-art
Authors:
- 14 January 2011
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (4) , 623-635
Abstract
Background: Permissible limits of analytical imprecision and bias are usually derived either from biological variability or from the state of the art. Both concepts require information from external sources which often lack transparency and are difficult to integrate in medical decision-making. Additionally, physicians may be interested in knowing the probability of decision errors due to analytical uncertainty. Therefore, an approach was developed which combines all three concepts. Methods: The empirical (observed) biological variation was derived from reference ranges used by the laboratory (CVE). CVE was corrected to get the biological variation in the theoretical absence of analytical imprecision (CVC). Relatively simple equations were derived from the relationship between biological variation and the analytical imprecision (CVA) to calculate permissible imprecision and bias. Five quality classes are proposed for the various analytes reflecting the false-positive error rates (FPR). These classes characterize analytical procedures according to their theoretical specificity (FPR). Thus, the new approach combines the theoretical base of biological variation with the technical state-of-the-art. Results and conclusions: As practical examples, the permissible imprecision and bias limits were estimated for a selection of quantities. The limits found were more realistic than present proposals based on Cotlove’s rule (fixed fraction of biological variation), but slightly more stringent than national consensus values based on the state-of-the-art. Imprecision and bias do not affect FPR equally, and, therefore, should be assessed separately. It is proposed to insert monthly imprecision and bias results calculated after each control cycle in a table with five quality classes. This table provides a simple overview of the analytical quality performance of the entire laboratory with one glance and can be handled on the Excel platform.Keywords
This publication has 24 references indexed in Scilit:
- Observed, unknown distributions of clinical chemical quantities should be considered to be log-normal: a proposalClinical Chemistry and Laboratory Medicine (CCLM), 2010
- Reference limits of plasma and serum creatinine concentrations from intra-laboratory data bases of several German and Italian medical centresClinica Chimica Acta, 2010
- An improved indirect approach for determining reference limits from intra-laboratory data bases exemplified by concentrations of electrolytes / Ein verbesserter indirekter Ansatz zur Bestimmung von Referenzgrenzen mittels intra-laboratorieller Datensätze am Beispiel von Elektrolyt-KonzentrationenJournal of Laboratory Medicine, 2009
- Proposed classification of various limit values (guide values) used in assisting the interpretation of quantitative laboratory test resultsClinical Chemistry and Laboratory Medicine (CCLM), 2009
- Within-subject biological variation in disease: collated data and clinical consequencesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2007
- A plea for intra-laboratory reference limits. Part 2. A bimodal retrospective concept for determining reference limits from intra-laboratory databases demonstrated by catalytic activity concentrations of enzymesClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Generation and Application of Data on Biological Variation in Clinical ChemistryCritical Reviews in Clinical Laboratory Sciences, 1989
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- Precision in a clinical chemistry laboratoryJournal of Clinical Pathology, 1967