Performance characteristics of a new prototype for a portable GC using ambient air as carrier gas for on‐site analysis
Authors:
- 25 April 2007
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 30 (7) , 1052-1060
Abstract
The performance characteristics of a portable GC instrument requiring no compressed gas supplies and using relatively lightweight transportable components for the analysis of volatile organic components in large‐volume air samples are described. To avoid the need for compressed gas tanks, ambient air is used as the carrier gas, and a vacuum pump is used to pull the carrier gas and injected samples through the wall‐coated capillary column and a photoionization detector (PID). At‐column heating is used eliminating the need for a conventional oven. The fused silica column is wrapped with heater wire and sensor wire so that heating is provided directly at the column. A PID is used since it requires no external gas supplies and has high sensitivity for many compounds of interest in environmental air monitoring. In order to achieve detection limits in the ppb range, an online multibed preconcentrator containing beds of graphitized carbons and carbon molecular sieves is used. After sample collection, the flow direction through the preconcentrator is reversed, and the sample is thermally desorbed directly into the column. Decomposition of sensitive compounds during desorption is greater with air as the carrier gas than with hydrogen.Keywords
This publication has 46 references indexed in Scilit:
- Gas ChromatographyAnalytical Chemistry, 2004
- A portable multi‐dimensional gas chromatographic system for field applicationsJournal of Separation Science, 2003
- High-Speed, Vacuum-Outlet GC Using Atmospheric-Pressure Air as Carrier GasAnalytical Chemistry, 1999
- Stepper Motor Controlled Micro Gas Valve Inlet System for Gas ChromatographyAnalytical Chemistry, 1998
- Megabore versus microbore as the optimal column for fast gas chromatography/mass spectrometryEuropean Journal of Mass Spectrometry, 1998
- A global model of natural volatile organic compound emissionsJournal of Geophysical Research: Atmospheres, 1995
- Dynamics and Response of Polymer-Coated Surface Acoustic Wave Devices: Effect of Viscoelastic Properties and Film ResonanceAnalytical Chemistry, 1994
- Emissions of volatile organic compounds from vegetation and the implications for atmospheric chemistryGlobal Biogeochemical Cycles, 1992
- Theoretical and practical aspects of short open tubular columns at subambient pressures in gas chromatography/mass spectrometryAnalytical Chemistry, 1989
- Considerations on Speed of Separation, Detection, and Identification Limits in Capillary GC and GC/MSC R C Critical Reviews in Analytical Chemistry, 1988