Application of CFD Simulation to Predicting Upper‐Room UVGI Effectiveness
- 26 October 2012
- journal article
- research article
- Published by Wiley in Photochemistry and Photobiology
- Vol. 89 (4) , 799-810
Abstract
This study outlines the potential for Computational Fluid Dynamics (CFD) simulation to be used to predict upper‐room ultraviolet germicidal irradiation (UVGI) effectiveness to aid system design and the development of future guidance. A numerical study of two wall‐mounted UVGI lamps in a mechanically ventilated test chamber is used to assess the influence of modeling parameters on prediction of dose distribution and microorganism inactivation. Irradiance fields for both UVGI fixtures are obtained via radiometry and implemented in the model. A series of sensitivity studies consider the importance of UVGI field accuracy and computational grid and turbulence model selection. Results show that 2D irradiance fields are sufficient for calculating dose and in‐activation, whereas a 1D field is inadequate for modeling purposes. Further parametric studies consider the effects of ventilation parameters, UVGI lamp configuration and microorganism susceptibility. These demonstrate the feasibility of modeling the interaction of the airflow and UV field in a room to quantify the dose distribution. Microorganism in‐activation can also be accomplished by employing passive scalars and species transport models, however, further validation data are necessary before this can be used to make reliable quantitative predictions.Keywords
This publication has 31 references indexed in Scilit:
- Methodology for determining the susceptibility of airborne microorganisms to irradiation by an upper-room UVGI systemJournal of Aerosol Science, 2006
- Modelling the Performance of Upper Room Ultraviolet Germicidal Irradiation Devices in Ventilated Rooms: Comparison of Analytical and CFD MethodsIndoor and Built Environment, 2004
- Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet lightJournal of Aerosol Science, 2004
- Quality control of computational fluid dynamics in indoor environmentsIndoor Air, 2003
- Efficacy of ultraviolet germicidal irradiation of upper-room air in inactivating airborne bacterial spores and mycobacteria in full-scale studiesAtmospheric Environment, 2003
- A quantitative method for evaluating the germicidal effect of upper room UV fieldsJournal of Aerosol Science, 2002
- Photoreactivation in Airborne Mycobacterium parafortuitumApplied and Environmental Microbiology, 2001
- Effects of Relative Humidity on the Ultraviolet Induced Inactivation of Airborne BacteriaAerosol Science and Technology, 2001
- A Multi-Zone Model Evaluation of the Efficacy of Upper-Room Air Ultraviolet Germicidal IrradiationApplied Occupational and Environmental Hygiene, 1999
- Room Air Disinfection by Ultraviolet Irradiation of Upper AirArchives of Environmental Health: An International Journal, 1971