In Vivo Measurement of Human Corneal Impedance Value
Authors:
- Hiroshi SasakiHSHiroshi Sasaki
- 1 October 2016
- journal article
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (10) , 1305-1307
Abstract
To examine the validity of in vivo electrical corneal resistance (CR) measurements taken by a corneal resistance device (CRD).Eighty-two eyes (mean age ± SD, 50.1 ± 23.3; range, 22-87 years: 50 eyes of 33 males and 32 eyes of 17 females) of patients who had undergone cataract surgery and volunteers at the Kanazawa Medical University Hospital were enrolled. The CR was compared among gender; age; side, that is, left versus right eye; healthy (fluorescein-negative) versus epithelium-injured eyes (fluorescein-positive), corneal radius of curvature; corneal endothelial cell count; and corneal thickness.The mean ± SD of the CR in the 82 eyes was 273.2 ± 78.2 Ω. By age group, the mean ± SD CR was 283.3 ± 87.4 Ω (30 eyes) in the 20s, 275.0 ± 50.0 Ω (4 eyes) in the 30s, 266.7 ± 70.7 Ω (9 eyes) in the 40s, 257.1 ± 53.5 Ω (7 eyes) in the 50s, 242.9 ± 78.7 Ω (7 eyes) in the 60s, 266.7 ± 84.0 Ω (18 eyes) in the 70s, and 300.0 ± 81.6 Ω (7 eyes) in the 80s, with no significant difference among the groups. By gender, the mean ± SD CR was 270.0 ± 83.0 Ω (50 eyes) in males and 278.0 ± 71.0 Ω (32 eyes) in females. By side, the CR values were 282.9 ± 83.4 Ω (44 eyes) in the right eye, 265.9 ± 71.3 Ω (41 eyes) in the left eye, with no significant difference among the groups. By status, the values were 280.0 ± 70.0 Ω (44 eyes) in healthy eyes and 200.0 ± 144.2 Ω (13 eyes) in injured eyes, with a significant between-group difference (P = 0.009). The mean ± SD corneal thickness (0.56 ± 0.03 mm) in 46 healthy eyes was slightly correlated with the CR.The CRD quantitatively measured the CR in healthy eyes. The CR did not differ significantly by age, gender, or left versus right eye. The significant difference in CR between the healthy and injured eyes showed that the measurements have validity.Keywords
This publication has 10 references indexed in Scilit:
- A novel in vivo corneal trans-epithelial electrical resistance measurement deviceJournal of Pharmacological and Toxicological Methods, 2015
- The Transcorneal Penetration of Commercial Ophthalmic Formulations Containing Timolol Maleate in Rabbit EyesJournal of Ocular Pharmacology and Therapeutics, 2014
- New Trends in Quantitative Assessment of the Corneal Barrier FunctionSensors, 2014
- Safety comparison of additives in antiglaucoma prostaglandin (PG) analog ophthalmic formulationsClinical Ophthalmology, 2013
- Localization and Expression of Zonula Occludins-1 in the Rabbit Corneal Epithelium following Exposure to Benzalkonium ChloridePLOS ONE, 2012
- Quantitative evaluation of corneal epithelial injury caused by n-heptanol using a corneal resistance measuring device in vivoClinical Ophthalmology, 2012
- A non-invasive method for an in vivo assessment of corneal epithelium permeability through tetrapolar impedance measurementsBiosensors and Bioelectronics, 2012
- Non-invasive assessment of corneal endothelial permeability by means of electrical impedance measurementsMedical Engineering & Physics, 2010
- Very-High-Frequency Ultrasound Corneal Imaging as a New Tool for Early Diagnosis of Ocular Surface Toxicity in Rabbits Treated with a Preserved Glaucoma DrugOphthalmic Research, 2008
- Fluorophotometric Determination of the Corneal Epithelial Barrier after Penetrating KeratoplastyAmerican Journal of Ophthalmology, 1981