Analytical application of the poly(1H-1,2,4-triazole-3-thiol) modified gold electrode for high-sensitive voltammetric determination of catechol in tap and lake water samples
- 24 May 2019
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 99 (13) , 1298-1312
Abstract
In this work, a simple, sensitive and rapid method for the determination of trace amounts of catechol (CT) in aqueous media has been suggested. For this purpose, poly(1H-1,2,4-triazole-3-thiol) film was electrochemically deposited successfully at the gold electrode (Au/T3T). The electrochemical behaviour of CT was studied on the Au/T3T electrode by the cyclic voltammetry and differential pulse voltammetry techniques. The anodic peak current value and the concentration of CT showed a good linear relationship in the range of 0.015–2.8 µM. The limit of detection was found as 1.88 nM (S/N = 3). Besides, the reproducibility, repeatability, stability and interference measurements were also assayed. This sensor was applied successfully for the detection of CT in synthetic and real samples.Keywords
This publication has 49 references indexed in Scilit:
- High sensitive simultaneous determination of hydroquinone and catechol based on graphene/BMIMPF6 nanocomposite modified electrodeSensors and Actuators B: Chemical, 2011
- High sensitive simultaneous determination of catechol and hydroquinone at mesoporous carbon CMK-3 electrode in comparison with multi-walled carbon nanotubes and Vulcan XC-72 carbon electrodesElectrochimica Acta, 2009
- Electrosynthesis and electrochemical characterisation of phenazine polymers for application in biosensorsElectrochimica Acta, 2008
- Aminopyrene functionalized mesoporous silica for the selective determination of resorcinolTalanta, 2007
- Direct Analysis of Phenol, Catechol and Hydroquinone in Human Urine by Coupled-Column HPLC with Fluorimetric DetectionChromatographia, 2005
- Controlled self-assembly of thiol-terminated poly(amidoamine) dendrimer and gold nanoparticlesColloids and Surfaces A: Physicochemical and Engineering Aspects, 2005
- Room-temperature heterogeneous hydroxylation of phenol with hydrogen peroxide over Fe2+, Co2+ ion-exchanged Naβ zeoliteChemical Communications, 2003
- Determination of some catechol derivatives by a flow injection electrochemiluminescent inhibition methodTalanta, 2000
- Methylphenazonium-Modified Enzyme Sensor Based on Polymer Thick Films for Subnanomolar Detection of PhenolsAnalytical Chemistry, 1995
- Electrochemistry of quinones1988