Rates of Upgrade of ICD Recipients to CRT in Clinical Practice and the Potential Impact of the More Liberal Use of CRT at Initial Implant
Authors:
- Paul A. ScottPSPaul A. Scott
- Andrew WhittakerAWAndrew Whittaker
- Mehmood ZebMZMehmood Zeb
- WattsWAWatts
- Arthur M. YueAYArthur M. Yue
- 6 November 2011
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (1) , 73-80
Abstract
Background: Many implantable cardioverter defibrillator (ICD) recipients may develop indications for cardiac resynchronization therapy (CRT) during follow‐up. However, the actual upgrade rate during follow‐up in clinical practice is not known. Methods: We performed a single center retrospective observational study of all new ICD implants over 5 years (2003–2007). The rate of CRT upgrade of patients initially implanted with a single‐/dual‐chamber ICD during follow‐up was assessed. The impact of using alternative criteria on the need for CRT in ICD recipients at initial implant was also evaluated. Results: During the study period, there were 549 new ICD implants. The initial implant was a single/dual‐chamber ICD in 73% (n = 399) and a CRT‐D in 27% (n = 150). During follow‐up (48±20 months) of the 399 ICD recipients, 70 (17.5%) died and 15 (3.8%) were upgraded to CRT, including eight cases where left ventricular lead implant had been initially unsuccessful. Upgrade rates at 1, 3, and 5 years were 0.03%, 2.4%, and 5.1%, respectively. Using alternative CRT criteria (left ventricular ejection fraction [LVEF]≤30%, QRS ≥130 ms, New York Heart Association I‐IV) 42.6% (n = 234) of ICD recipients met criteria for CRT at initial implant. Conclusion: In this retrospective single center study, rates of CRT upgrade in ICD recipients over the medium term were low, which may reflect underuse in otherwise appropriate candidates. The more liberal use of CRT at initial implant in patients with a reduced LVEF, a broad QRS, but only mild heart failure symptoms would require approximately 50% increase in CRT use in ICD recipients at initial implant, and may help address some of the suggested underutilization. (PACE 2012; 35:73–80)Keywords
This publication has 13 references indexed in Scilit:
- Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart FailureNew England Journal of Medicine, 2010
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Impact of Implantable Cardioverter-Defibrillator, Amiodarone, and Placebo on the Mode of Death in Stable Patients With Heart FailureCirculation, 2009
- Maximizing Survival Benefit With Primary Prevention Implantable Cardioverter-Defibrillator Therapy in a Heart Failure PopulationCirculation, 2009
- Time‐Dependence of Appropriate Implantable Defibrillator Therapy in Patients with Ischemic CardiomyopathyJournal of Cardiovascular Electrophysiology, 2008
- Patients with heart failure who require an implantable defibrillator should have cardiac resynchronisation routinelyHeart, 2008
- Development of indications for cardiac resynchronisation therapy in the implantable cardioverter defibrillator populationInternational Journal of Cardiology, 2005
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary ArticleCirculation, 2002
- Partial residuals for the proportional hazards regression modelBiometrika, 1982