Abstract
Objective. Real-time six-degree-of-freedom (6DoF) tumour motion monitoring is important for accurate stereotactic body radiotherapy (SBRT) of thoracic and abdominal cancer sites, yet existing approaches either require specialised imaging hardware or continuous fluoroscopic imaging. This study presents the development and first experimental implementation of a real-time image-guided 6DoF internal-external correlation (6D-IEC) modelling framework on a standard linear accelerator. Approach. The 6D-IEC framework estimates 6DoF tumour motion using a state-augmented linear correlation model between a 1DoF external respiratory monitor and internal fiducial marker positions, updated with intrafraction kV images every 3 s. Performance was characterised through two complementary evaluations: a prospective experimental investigation on a robotic motion platform, providing independent ground truth across eight patient-measured lung and liver motion traces (3 regular, 5 irregular); and a patient data study using intrafraction imaging data from three patients treated in the TROG 17.03 LARK liver SBRT trial (NCT02984566). 6DoF geometric error was quantified for both evaluations; software processing latency was measured in the experimental investigation. Main results. In the experimental investigation, mean ± SD geometric errors were 0.1 ± 1.0 mm, 0.3 ± 1.9 mm, and −0.3 ± 1.4 mm along the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) translational axes, and 0.4°± 1.2°, −0.8°± 1.0°, and −0.2°± 0.8° around the corresponding rotational axes (rLR, rSI, rAP). Software processing latency was 190 ± 80 ms. In the patient data study, errors were −0.5 ± 0.7 mm, −1.2 ± 2.5 mm, −0.1 ± 1.0 mm (LR, SI, AP), and 1.1°± 1.7°, −0.9°± 1.5°, and −0.4°± 1.6° (rLR, rSI, rAP). Significance. This work demonstrates that real-time 6DoF motion monitoring with clinically relevant accuracy is achievable on a standard linear accelerator without specialised hardware or continuous kV imaging. 6D-IEC infers tumour motion from an external signal between imaging updates, with accuracy contingent on IEC, but requires approximately 95% fewer intrafraction kV images than continuous fluoroscopic approaches. This has implications for broader access to real-time image-guided radiotherapy.Keywords
Funding Information
- Australian government Medical Research Future Fund (NCRI000139)
- Australian Government National Health and Medical Research Council (2041792)
- Australian Academy of Technological Sciences and Engineering Elevate: Boosting Diversity in STEM PhD Scholarship
- Sydney Cancer Partners SEED grant (2023/CBG0002)
- Cancer Institute NSW (2024/ECF1592)
- Australian Government Research Training Program Scholarship
This publication has 43 references indexed in Scilit:
- Clinical implementation and patient‐specific quality assurance solutions for real‐time target tracking and dynamic delivery in Radixact synchronyJournal of Applied Clinical Medical Physics, 2024
- Stability analysis of patient‐specific 4DCT‐ and 4DCBCT‐based correspondence modelsMedical Physics, 2024
- How much rotational error is clinically acceptable for single‐isocenter/two‐lesion lung SBRT treatment on halcyon ring delivery system (RDS)?Journal of Applied Clinical Medical Physics, 2023
- Magnetic Resonance Imaging–Guided vs Computed Tomography–Guided Stereotactic Body Radiotherapy for Prostate CancerJAMA Oncology, 2023
- The dosimetric error due to uncorrected tumor rotation during real‐time adaptive prostate stereotactic body radiation therapyMedical Physics, 2022
- ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X‐ray positioningJournal of Applied Clinical Medical Physics, 2022
- AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapyMedical Physics, 2020
- Utilizing the TrueBeam Advanced Imaging Package to monitor intrafraction motion with periodic kV imaging and automatic marker detection during VMAT prostate treatmentsJournal of Applied Clinical Medical Physics, 2020
- A deep learning framework for automatic detection of arbitrarily shaped fiducial markers in intrafraction fluoroscopic imagesMedical Physics, 2019
- Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurementJournal of Applied Clinical Medical Physics, 2017