Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability
Open Access
- 6 May 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (3) , 1024-1034
Abstract
Purpose: To develop arrhythmia‐insensitive inversion recovery sequences for improved visualization of myocardial scar and quantification of diffuse fibrosis.Methods: A novel preparation pre‐pulse, called saturation pulse prepared heart‐rate‐independent inversion recovery, is introduced, which consists of a combination of saturation and inversion pulses to remove the magnetization history in each heartbeat in late gadolinium enhancement (LGE) imaging and eliminate the need for rest periods in T1 mapping. The proposed LGE and T1 mapping sequences were evaluated against conventional LGE and modified Look‐Locker inversion sequences using numerical simulations, phantom and imaging in healthy subjects and patients with suspected or known cardiovascular disease.Results: Simulations and phantom experiments show that the saturation pulse prepared heart‐rate‐independent inversion recovery pre‐pulse in LGE reduces ghosting artifacts and results in perfect nulling of the healthy myocardium in the presence of arrhythmia. In T1 mapping, saturation pulse prepared heart‐rate‐independent inversion recovery results in (a) reduced scan time (17 vs. 9 heartbeats), (b) insensitivity to heart rate for long T1, and (c) increased signal homogeneity for short T1. LGE images in a patient in atrial fibrillation during the scan show improved myocardial nulling. In vivo T1 maps demonstrate increased signal homogeneity in blood pools and myocardium.Conclusion: The proposed sequences are insensitive to heart rate variability, yield improved LGE images in the presence of arrhythmias, as well as T1 mapping with shorter scan times. Magn Reson Med 71:1024–1034, 2014. © 2013 Wiley Periodicals, Inc.Keywords
Funding Information
- NIH (R01EB008743-01A2)
- Deutsche Telekom Stiftung
This publication has 35 references indexed in Scilit:
- T2-dependent errors in MOLLI T1 values: simulations, phantoms, and in-vivo studiesJournal of Cardiovascular Magnetic Resonance, 2012
- Heart Disease and Stroke Statistics—2012 UpdateCirculation, 2012
- Assessment of Diffuse Myocardial Fibrosis in Rats Using Small-Animal Look-Locker Inversion Recovery T1 MappingCirculation: Cardiovascular Imaging, 2011
- Myocardial T1 mapping with MRI: Comparison of look‐locker and MOLLI sequencesJournal of Magnetic Resonance Imaging, 2011
- Myocardial extravascular extracellular volume fraction measurement by gadolinium cardiovascular magnetic resonance in humans: slow infusion versus bolusJournal of Cardiovascular Magnetic Resonance, 2011
- Coronary MR Imaging: Effect of Timing and Dose of Isosorbide Dinitrate AdministrationRadiology, 2010
- Detection and Quantification of Left Atrial Structural Remodeling With Delayed-Enhancement Magnetic Resonance Imaging in Patients With Atrial FibrillationCirculation, 2009
- Recurrence of Atrial Fibrillation Correlates With the Extent of Post-Procedural Late Gadolinium EnhancementJACC: Cardiovascular Imaging, 2009
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004