Efforts to improve detection sensitivity for capillary electrophoresis coupled to atmospheric pressure photoionization mass spectrometry
Open Access
- 7 April 2010
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (9) , 1260-1264
Abstract
Electrospray ionization performs best with volatile buffers. However, generally the best separation performance for capillary electrophoresis (CE) is achieved with non‐volatile buffers. Hyphenation of CE with mass spectrometry (MS) utilizing atmospheric pressure photoionization (APPI) enables use of a wider range of separation buffers without compromising detection sensitivity. As APPI is considered to be mass flow sensitive, the use of a larger inner diameter separation capillary (75 µm) allows larger volumes to be injected, without decreased separation performance, thus providing improved sensitivity (approx. a factor of 10), compared to the use of a 25 µm capillary. However, nebulizing gas flow and position of capillary tip in the sprayer have to be carefully optimized to prevent excessive band broadening. Further improvement in sensitivity (approx. a factor of 2) was obtained by decreasing the distance between the sprayer and ionization region, indicating that a specially designed CE/APPI‐MS interface for low flow rates will be favourable. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 27 references indexed in Scilit:
- Recent applications of capillary electrophoresis‐electrospray ionisation‐mass spectrometry in drug analysisElectrophoresis, 2006
- Factors affecting primary ionization in dopant-assisted atmospheric pressure photoionization (DA-APPI) for LC/MSJournal of the American Society for Mass Spectrometry, 2006
- Recent advances in capillary electrophoresis and capillary electrochromatography of pollutantsElectrophoresis, 2003
- Atmospheric pressure photoionization mass spectrometryMass Spectrometry Reviews, 2003
- Capillary electrophoresis mass spectrometry and its application to the analysis of biological mixturesAnalytical and Bioanalytical Chemistry, 2002
- Atmospheric Pressure Photoionization: An Ionization Method for Liquid Chromatography−Mass SpectrometryAnalytical Chemistry, 2000
- Effects of salt concentration on analyte response using electrospray ionization mass spectrometryJournal of the American Society for Mass Spectrometry, 1999
- On-Column Sample Concentration Using Field Amplification in CZEAnalytical Chemistry, 1992
- Electroosmotic properties and peak broadening in field-amplified capillary electrophoresisAnalytical Chemistry, 1991
- On-line mass spectrometric detection for capillary zone electrophoresisAnalytical Chemistry, 1987