Intramedullary Nailing Supplemented with Poller Screws for Proximal Tibial Fractures
Open Access
- 1 December 2012
- journal article
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 20 (3) , 307-311
Abstract
Purpose. To evaluate outcome of intramedullary nailing supplemented with Poller screws for proximal tibial fractures using small diameter nails. Methods. 50 men and 20 women (75 fractures) aged 18 to 65 (mean, 33) years underwent intramedullary nailing supplemented with Poller screws for acutely displaced fractures (n=60) or for delayed union (n=10) or mal-union (n=5) of the proximal metadiaphyseal tibia. 88% of the fractures were caused by road traffic accidents. 54 cases had closed fractures and 21 had grade I or II compound fractures. Clinical and radiological outcome was evaluated. Results. In 69 cases, healing occurred after a mean of 4.2 (range, 3–9) months. In 5 cases, there was nonunion, which was resolved by bone grafting. One case was mal-united. 63 patients recovered a full range of knee motion (0°–130°), and the remaining 7 attained flexion of 0° to 90°. According to the knee rating scale of the Hospital for Special Surgery, outcome was excellent in 50 patients, good in 14, poor in 3, and failed in 3 at month 12, and remained so after a mean follow-up of 30.8 months. Postoperatively, 74 cases had Conclusion. Poller screws help maintain fixation of intramedullary nailing and alignment of fractures.Keywords
This publication has 10 references indexed in Scilit:
- The Logic and Clinical Applications of Blocking ScrewsJournal of Bone and Joint Surgery, 2004
- Fractures of the Proximal Third of the Tibial Shaft Treated With Intramedullary Nails and Blocking ScrewsJournal of Orthopaedic Trauma, 2001
- Nonarticular Proximal Tibia Fractures: Treatment Options and Decision MakingJournal of the American Academy of Orthopaedic Surgeons, 2001
- The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nailsThe Journal of Bone and Joint Surgery. British volume, 1999
- The Mechanical Effect of Blocking Screws ("Poller Screws") in Stabilizing Tibia Fractures With Short Proximal or Distal Fragments After Insertion of Small-Diameter Intramedullary NailsJournal of Orthopaedic Trauma, 1999
- The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nailsThe Journal of Bone and Joint Surgery. British volume, 1999
- Semiextended Position for Intramedullary Nailing of the Proximal TibiaClinical Orthopaedics and Related Research, 1996
- Unreamed intramedullary nailing of femoral shaft fractures: operative technique and early clinical experience with the standard locking optionInjury, 1996
- Influences of Some Design Parameters on the Biomechanics of the Unreamed Tibial Intramedullary NailJournal of Orthopaedic Trauma, 1993
- Häufigkeit und Ursachen von Fehlstellungen nach UnterschenkelmarknagelungenEuropean Journal of Trauma and Emergency Surgery, 1992