Surface Electromyography With Wearable Graphene Textiles
- 1 January 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14397-14406
Abstract
In this study, we report the use of graphene-coated fabrics as textile electrodes in surface electromyography (sEMG) acquisition. Their performance was compared with that of wet silver/silver chloride (Ag/AgCl) electrodes for the signals that were taken from three different muscle groups. Comparisons were performed in terms of the skin-electrode impedance (SEI), signal-to-noise ratio (SNR) and cross correlation. SEI values of graphene textile electrodes ( $\sim 90\text{k}\Omega $ ) were found to be well within the range of commercial Ag/AgCl electrodes ( $\sim 50\text{k}\Omega $ ). At 2 kg load, SNR values of 19.23 dB from triceps brachii, 27.18 dB from biceps brachii, and 28.13 dB from quadriceps femoris muscles were obtained, respectively; which showed that performance of graphene textile electrodes in static settings is at minimum 94% of clinical signal quality both in terms of SNR and similarity of signal morphologies in terms of cross correlation. After benchmarking the electrode performance, a proof of concept fully textile elastic band and a mobile acquisition circuit were combined to further validate the feasibility of surface electromyography with wearable graphene textiles through a step counter application, where the implemented wearable graphene textile-based step counter achieved on average a success rate above 90% for varying speed levels and up to a maximum of ~98%. Results suggests that graphene textiles could be a viable alternative to gelled Ag/AgCl electrodes and can be used to develop wearable, smart garment applications.
Keywords
Funding Information
- Sabanci University
- Scientific and Technological Research Council of Turkey (119C091)
This publication has 33 references indexed in Scilit:
- Effect of pressure and padding on motion artifact of textile electrodesBioMedical Engineering OnLine, 2013
- Ventilatory threshold during incremental running can be estimated using EMG shortsPhysiological Measurement, 2012
- Design and development of embroidered textile electrodes for continuous measurement of electrocardiogram signalsJournal of Industrial Textiles, 2012
- An Autonomous Wearable System for Predicting and Detecting Localised Muscle FatigueSensors, 2011
- Textile electrodes of jacquard woven fabrics for biosignal measurementThe Journal of the Textile Institute, 2010
- Normative EMG activation patterns of school-age children during gaitGait & Posture, 2010
- Teager–Kaiser energy operator signal conditioning improves EMG onset detectionEuropean Journal of Applied Physiology, 2010
- Electromyographic Biofeedback for the Recovery of Motor Function After StrokeStroke, 2007
- ECG measurement on a chair without conductive contactIEEE Transactions on Biomedical Engineering, 2006
- Normalization of upper trapezius EMG amplitude in ergonomic studiesJournal of Electromyography and Kinesiology, 1995