Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures
Open Access
- 6 September 2016
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 6 (9) , 248
Abstract
Load-bearing cold-formed steel (CFS) walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall system. However, studies on the mechanical behavior of screw connections with double-layer gypsum sheathing are still limited. In this study, 200 monotonic tests of screw connections with single- or double-layer gypsum sheathing at both ambient and elevated temperatures were conducted. The failure of screw connections with double-layer gypsum sheathing in shear was different from that of single-layer gypsum sheathing connections at ambient temperature, and it could be described as the breaking of the loaded sheathing edge combined with significant screw tilting and the loaded sheathing edge flexing fracture. However, the screw tilting and flexing fracture of the loaded sheathing edge gradually disappear at elevated temperatures. In addition, the influence of the loaded edge distance, double-layer sheathing and elevated temperatures is discussed in detail with clear conclusions. A unified design formula for the shear strength of screw connections with gypsum sheathing is proposed for ambient and elevated temperatures with adequate accuracy. A simplified load–displacement model with the post-peak branch is developed to evaluate the load–displacement response of screw connections with gypsum sheathing at ambient and elevated temperatures.Keywords
Funding Information
- National Natural Science Foundation of China (51508088)
- Natural Science Foundation of Jiangsu Province of China (BK20150605)
- Key Laboratory of Building Fire Protection Engineering and Technology of Ministry of Public Security of the People's Republic of China (KFKT2015ZD05)
- Key Laboratory of Environmental Impact and Structural Safety in Engineering (JSKL2014K04)
- Jiangsu Key Laboratory of Structure Engineering (ZD1402)
This publication has 18 references indexed in Scilit:
- Experimental study on shear behavior of screw connections in CFS sheathingJournal of Constructional Steel Research, 2016
- Behavior of Screw and Adhesive Connections to Gypsum Wallboard in Wood and Cold-Formed Steel-Framed WallettesJournal of Structural Engineering, 2016
- Hysteretic characterization of cold-formed steel stud-to-sheathing connectionsJournal of Constructional Steel Research, 2014
- Improved fire resistant performance of load bearing cold-formed steel interior and exterior wall systemsThin-Walled Structures, 2013
- Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panelsJournal of Constructional Steel Research, 2012
- Experimental study of screw connections in CFS-calcium silicate board wall panelsThin-Walled Structures, 2011
- Experimental tests on typical screw connections for cold-formed steel housingEngineering Structures, 2007
- Design Criteria for Seam and Sheeting-to-Framing Connections of Cold-Formed Steel Shear PanelsJournal of Structural Engineering, 2006
- Fire Resistance of Walls and Floors Using Light-Gauge Steel ShapesJournal of Structural Engineering, 2003
- Static Racking Behavior of Plywood, OSB, Gypsum, and FiberBond Walls with Metal FramingJournal of Structural Engineering, 1997