An extended XY coil for noise reduction in inductive-coupling link

Authors:

Abstract
Inductive-coupling link between stacked chips in a package communicates by using coils made by on-chip interconnections. An XY-coil layout style allows logic interconnections to go through the coil, which significantly saves interconnection resources consumed by the coil. However, the logic interconnections generate capacitive-coupling noise on the coil and degrade signal in the inductive-coupling link. In this paper, an extended XY coil with ground shields is presented for noise reduction. Simulation study shows that the noise voltage is reduced to 1/5 of the conventional XY coil. This noise reduction enables to reduce transmit power required for the same BER. Test-chip measurement in 0.18 ¿m CMOS demonstrates that the transmit power at lGb/s with BER-12 is reduced by 60% compared to the conventional XY coil.