Videokeratoscope–line-of-sight misalignment and its effect on measurements of corneal and internal ocular aberrations
- 1 April 2002
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 19 (4) , 657-669
Abstract
A growing number of research laboratories are using the new technologies of videokeratoscopy and Shack–Hartmann aberrometry, in combination, to study the optical structure of the human eye. A potential source of error arises, however, because the two instruments are designed to measure the human eye along different reference axes. The Shack–Hartmann aberrometer is usually aligned coaxially with the line of sight, but videokeratoscopes usually are not. Thus far, corneal optics research has not adequately addressed the problem of videokeratoscope–line-of-sight misalignment and its effect on the computation of corneal and internal ocular aberrations. We measured corneal, ocular, and internal aberrations for three normal human eyes, developed a method to compensate for videokeratoscope–line-of-sight misalignment, and analyzed the importance of compensating for the misalignment. Our results show that when the value of angle lambda (the angle between the line of sight and the pupillary axis) is larger than 2°–3°, the misalignment, if ignored, can lead to incorrect estimates of corneal and internal aberrations as well as the corneal/internal aberration balance.Keywords
This publication has 30 references indexed in Scilit:
- Compensation of corneal aberrations by the internal optics in the human eyeJournal of Vision, 2001
- Analysis of the performance of the Hartmann–Shack sensor in the human eyeJournal of the Optical Society of America A, 2000
- Accuracy of the EyeSys 2000 in measuring surface elevation of calibrated aspheresInternational Contact Lens Clinic, 1998
- Optimal corneal ablation for eyes with arbitrary Hartmann–Shack aberrationsJournal of the Optical Society of America A, 1998
- Outcomes Research???Translating Efficacy into EffectivenessOptometry and Vision Science, 1998
- Spherical Aberration of the Reduced Schematic Eye with Elliptical Refracting SurfaceOptometry and Vision Science, 1997
- Corneal optics from videokeratographsOphthalmic and Physiological Optics, 1995
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994
- The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humansApplied Optics, 1992
- Contribution of the crystalline lens to the spherical aberration of the eyeJournal of the Optical Society of America, 1973