Ultrasonically actuated neural probes for reduced trauma and inflammation in mouse brain
Open Access
- 2 November 2022
- journal article
- research article
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-15
Abstract
Electrical neural recordings measured using direct electrical interfaces with neural tissue suffer from a short lifespan because the signal strength decreases over time. The inflammatory response to the inserted microprobe can create insulating tissue over the electrical interfaces, reducing the recorded signal below noise levels. One of the factors contributing to this inflammatory response is the tissue damage caused during probe insertion. Here, we explore the use of ultrasonic actuation of the neural probe during insertion to minimize tissue damage in mice. Silicon neural microprobes were designed and fabricated with integrated electrical recording sites and piezoelectric transducers. The microprobes were actuated at ultrasonic frequencies using integrated piezoelectric transducers. The microprobes were inserted into mouse brains under a glass window over the brain surface to image the tissue surrounding the probe using two-photon microscopy. The mechanical force required to penetrate the tissue was reduced by a factor of 2–3 when the microprobe was driven at ultrasonic frequencies. Tissue histology at the probe insertion site showed a reduced area of damage and decreased microglia counts with increasing ultrasonic actuation of the probes. Two-photon imaging of the microprobe over weeks demonstrated stabilization of the inflammatory response. Recording of electrical signals from neurons over time suggests that microprobes inserted using ultrasound have a higher signal-to-noise ratio over an extended time period.Keywords
Funding Information
- National Science Foundation (1744271)
- United States Department of Defense | Defense Advanced Research Projects Agency (HIST)
This publication has 46 references indexed in Scilit:
- Implantable Devices: Issues and ChallengesElectronics, 2012
- Cortical Microhemorrhages Cause Local Inflammation but Do Not Trigger Widespread Dendrite DegenerationPLOS ONE, 2011
- Generalized response of a sphere embedded in a viscoelastic medium excited by an ultrasonic radiation forceThe Journal of the Acoustical Society of America, 2011
- Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobesJournal of Micromechanics and Microengineering, 2011
- Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodesJournal of Neural Engineering, 2011
- In VivoPenetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer ScalesIEEE Transactions on Biomedical Engineering, 2008
- Demonstration of cortical recording using novel flexible polymer neural probesSensors and Actuators A: Physical, 2008
- In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortexIEEE Transactions on Biomedical Engineering, 2006
- Cortical Ensemble Adaptation to Represent Velocity of an Artificial Actuator Controlled by a Brain-Machine InterfaceJournal of Neuroscience, 2005
- Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissueJournal of Biomedical Materials Research, 1993