Contact localization through spatially overlapping piezoresistive signals
Authors:
- 1 December 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-201
Abstract
Achieving high spatial resolution in contact sensing for robotic manipulation often comes at the price of increased complexity in fabrication and integration. One traditional approach is to fabricate a large number of taxels, each delivering an individual, isolated response to a stimulus. In contrast, we propose a method where the sensor simply consists of a continuous volume of piezoresistive elastomer with a number of electrodes embedded inside. We measure piezoresistive effects between all pairs of electrodes in the set, and count on this rich signal set containing the information needed to pinpoint contact location with high accuracy using regression algorithms. In our validation experiments, we demonstrate submillimeter median accuracy in locating contact on a 10mm by 16mm sensor using only four electrodes (creating six unique pairs). In addition to extracting more information from fewer wires, this approach lends itself to simple fabrication methods and makes no assumptions about the underlying geometry, simplifying future integration on robot fingers.Keywords
All Related Versions
This publication has 30 references indexed in Scilit:
- Object manifold learning with action features for active tactile object recognition2014
- Grasp adjustment on novel objects using tactile experience from similar local geometry2013
- Design and Characterization of a Soft Multi-Axis Force Sensor Using Embedded Microfluidic ChannelsIEEE Sensors Journal, 2013
- Improved Dispersion of Carbon Nanotubes in Polymers at High ConcentrationsNanomaterials, 2012
- Assessing Grasp Stability Based on Learning and Haptic DataIEEE Transactions on Robotics, 2011
- Active estimation of object dynamics parameters with tactile sensors2010
- Monolithic silicon smart tactile image sensor with integrated strain sensor array on pneumatically swollen single-diaphragm structureIEEE Transactions on Electron Devices, 2006
- A large-area, flexible pressure sensor matrix with organic field-effect transistors for artificial skin applicationsProceedings of the National Academy of Sciences, 2004
- A traction stress sensor array for use in high-resolution robotic tactile imagingJournal of Microelectromechanical Systems, 2000
- A 1024-element high-performance silicon tactile imagerIEEE Transactions on Electron Devices, 1990