Near monochromatic X-rays for digital slot-scan mammography: initial findings
- 30 June 2004
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 14 (9) , 1641-1646
Abstract
X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography.Keywords
This publication has 20 references indexed in Scilit:
- Dosiseinsparung durch rasterlose Technik in der digitalen VollfeldmammographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Initiation of population-based mammography screening in Dutch municipalities and effect on breast-cancer mortality: a systematic reviewThe Lancet, 2003
- Research at the European Synchrotron Radiation Facility medical beamline.2000
- Is screening for breast cancer with mammography justifiable?The Lancet, 2000
- Glandular Breast Dose for Monoenergetic and High-Energy X-ray Beams: Monte Carlo AssessmentRadiology, 1999
- Full field digital mammography scannerEuropean Journal of Radiology, 1999
- Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissuePhysics in Medicine & Biology, 1998
- Near-Monochromatic X-ray Beams Produced by the Free Electron Laser and Compton BackscatterInvestigative Radiology, 1990
- Optimal x‐ray spectra for screen‐film mammographyMedical Physics, 1981
- Investigation of 125I as an Isotopic Source for MammographyInvestigative Radiology, 1975