Evaluation of the Antimicrobial Activity and Materials Compatibility of Orthophthalaldehyde as a High-level Disinfectant
Authors:
Open Access
- 1 March 2005
- journal article
- research article
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 33 (2) , 178-187
Abstract
We tested the antimicrobial activity of orthophthalaldehyde (OPA) against 21 strains (16 species) of pathogenic microorganisms that cause hospital-associated infections. Changes in hepatitis B surface antigen (HBs-Ag) resulting from the addition of OPA to HBs-Ag-positive serum were measured using a radio-immunoassay. We also examined the effect of immersing medical instruments in OPA (0.55%) for 168 h at room temperature. OPA (0.5%, 0.37% and 0.25%) killed 11 strains of vegetative bacteria within 15 s, and it killed the test microorganisms faster than 3.0% glutaraldehyde (GTA). Incubation with OPA or GTA caused levels of HBs-Ag to fall below a cut-off value within 30 s. OPA did not adversely affect instruments made from various materials. OPA demonstrated more effective antimicrobial activity than GTA against a range of microorganisms. We conclude that OPA should replace GTA as the first-choice high-level disinfectant for endoscopes, considering its antimicrobial efficacy and low inhalation toxicity.Keywords
This publication has 13 references indexed in Scilit:
- FAILURE OF REACTIVATION OF HEPATITIS B AFTER LIVER TRANSPLANTATION IN HEPATITIS B SURFACE ANTIGEN-NEGATIVE, CORE ANTIBODY-POSITIVE RECIPIENTSTransplantation, 2002
- Ortho‐phthalaldehyde: a possible alternative to glutaraldehyde for high level disinfectionJournal of Applied Microbiology, 1999
- Disinfection of Endoscopes: Review of New Chemical Sterilants Used for High-Level DisinfectionInfection Control & Hospital Epidemiology, 1999
- Mycobacterium terrae: a potential surrogate for Mycobacterium tuberculosis in a standard disinfectant testJournal of Hospital Infection, 1998
- Transmission of Helicobacter pylori infection via flexible fiberoptic endoscopyAmerican Journal of Infection Control, 1996
- Epistaxis Due to Glutaraldehyde ExposureJournal of Occupational and Environmental Medicine, 1989
- Occupational contact dermatitis due to glutaraldehyde in health care workersContact Dermatitis, 1988
- Asthma and Rhinitis after Exposure to Glutaraldehyde in Endoscopy UnitsHuman Toxicology, 1986
- Preliminary Evaluation of an Activated Glutaraldehyde Solution for Cold SterilizationAnnals of Surgery, 1965
- Alkalinized Glutaraldehyde, a New Antimicrobial AgentJournal of Pharmaceutical Sciences, 1964