Reliability and Validity of Running Cadence and Stance Time Derived from Instrumented Wireless Earbuds
Open Access
Abstract
Instrumented earbuds equipped with accelerometers were developed in response to limitations of currently used running wearables regarding sensor location and feedback delivery. The aim of this study was to assess test–retest reliability, face validity and concurrent validity for cadence and stance time in running. Participants wore an instrumented earbud (new method) while running on a treadmill with embedded force-plates (well-established method). They ran at a range of running speeds and performed several instructed head movements while running at a comfortable speed. Cadence and stance time were derived from raw earbud and force-plate data and compared within and between both methods using t-tests, ICC and Bland–Altman analysis. Test–retest reliability was good-to-excellent for both methods. Face validity was demonstrated for both methods, with cadence and stance time varying with speed in to-be-expected directions. Between-methods agreement for cadence was excellent for all speeds and instructed head movements. For stance time, agreement was good-to-excellent for all conditions, except while running at 13 km/h and shaking the head. Overall, the measurement of cadence and stance time using an accelerometer embedded in a wireless earbud showed good test–retest reliability, face validity and concurrent validity, indicating that instrumented earbuds may provide a promising alternative to currently used wearable systems.Keywords
Funding Information
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (P16-28)
This publication has 43 references indexed in Scilit:
- Gait asymmetry detection in older adults using a light ear-worn sensorPhysiological Measurement, 2014
- Gait Parameter Estimation From a Miniaturized Ear-Worn Sensor Using Singular Spectrum Analysis and Longest Common SubsequenceIEEE Transactions on Biomedical Engineering, 2014
- Comparison of vertical ground reaction forces during overground and treadmill running. A validation studyBMC Musculoskeletal Disorders, 2012
- Validation of an ear-worn sensor for gait monitoring using a force-plate instrumented treadmillGait & Posture, 2012
- The use of a single inertial sensor to identify stride, step, and stance durations of running gaitJournal of Science and Medicine in Sport, 2010
- Portable Activity Monitoring System for Temporal Parameters of Gait CyclesJournal of Medical Systems, 2009
- Gait Analysis on Split-Belt Force TreadmillsAmerican Journal of Physical Medicine & Rehabilitation, 2008
- Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditionsPhysiological Measurement, 2008
- A kinematic and kinetic comparison of overground and treadmill walking in healthy subjectsGait & Posture, 2007
- Ankle plantar flexor force production is an important determinant of the preferred walk-to-run transition speedJournal of Experimental Biology, 2005