Combined cataract–glaucoma surgery using the intracanalicular Eyepass glaucoma implant
Authors:
- Thomas Stefan DietleinTDThomas Stefan Dietlein
- Jens Friedrich JordanJJJens Friedrich Jordan
- Andrea SchildASAndrea Schild
- Walter KonenWKWalter Konen
- Anselm JünemannAJAnselm Jünemann
- Christoph LükeCLChristoph Lüke
- Günter Karl KrieglsteinGKGünter Karl Krieglstein
- 1 February 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (2) , 247-252
Abstract
To study prospectively the safety and pressure-reducing efficacy of the Y-shaped Eyepass glaucoma implant (GMP Vision Solutions, Inc.). Departments of Ophthalmology, University of Cologne, Cologne, and University of Erlangen, Erlangen, Germany. This study comprised 12 patients with primary open-angle or exfoliative glaucoma and cataract who had phacoemulsification with endocapsular implantation of a foldable intraocular lens and intracanalicular implantation of an Eyepass glaucoma implant. The implant is a silicone microtube shunt that bypasses the trabecular meshwork and connects the lumina of Schlemm canal with the anterior chamber in combined cataract–glaucoma surgery. Perioperative complications, intraocular pressure (IOP), and pressure-reducing topical medications were monitored over a preliminary follow-up. Perforation of the trabecular meshwork during Eyepass implantation occurred in 2 eyes; the antiglaucoma procedure was converted to trabeculotomy after the shunt was explanted, and both eyes were excluded from further follow-up. In the remaining 10 eyes, the mean maximum IOP was 30.4 mm Hg ± 7.5 (SD) (range 21 to 46 mm Hg) preoperatively, 12.0 ± 6.1 mm Hg (range 2 to 20 mm Hg) 1 day postoperatively, 17.2 ± 4.1 mm Hg (range 12 to 27 mm Hg) at 4 weeks, and 18.3 ± 4.5 mm Hg (range 12 to 25 mm Hg) at the end of the preliminary follow-up. The mean number of topical medications was 3.2 ± 0.8 preoperatively and 0.9 ± 0.7 at the end of follow-up (mean 7.1 months). Although there were no major complications requiring surgical revision, 4 eyes had an IOP of 18 or higher at the end of follow-up. Combined cataract surgery with Eyepass shunt implantation was safe and appeared to be beneficial in glaucomatous eyes with cataract not requiring a low target IOP.Keywords
This publication has 20 references indexed in Scilit:
- Seven-year follow-up of combined cataract extraction and viscocanalostomyJournal of Cataract & Refractive Surgery, 2006
- Phaco‐trabeculotomy combined with deep sclerectomy, a new technique in combined cataract and glaucoma surgery: complication profileActa Ophthalmologica Scandinavica, 2006
- Frühe postoperative Augeninnendruckspitzen nach Phakoemulsifikation bei terminalen GlaukomenKlinische Monatsblätter für Augenheilkunde, 2006
- Combined cataract and glaucoma surgery with mitomycin C: phacoemulsification-trabeculectomy compared to phacoemulsification-deep sclerectomyBritish Journal of Ophthalmology, 2005
- Filtering bleb function after clear cornea phacoemulsification: a prospective studyBritish Journal of Ophthalmology, 2005
- Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsificationBritish Journal of Ophthalmology, 2005
- Effect of technique on intraocular pressure after combined cataract and glaucoma surgeryOphthalmology, 2002
- Morphological variability of the trabecular meshwork in glaucoma patients: implications for non-perforating glaucoma surgeryBritish Journal of Ophthalmology, 2000
- Glaukom und Katarakt: Operation ein- oder zweizeitig?123Klinische Monatsblätter für Augenheilkunde, 2000
- Combined surgery for cataractand glaucoma: Phacoemulsification and deep sclerectomy compared with phacoemulsification and trabeculectomyJournal of Cataract & Refractive Surgery, 1999