Low-fluence vs. standard fluence hair removal: A contralateral control non-inferiority study
Authors:
- Shlomit HalachmiSHShlomit Halachmi
- Moshe LapidothMLMoshe Lapidoth
Open Access
- 30 November 2011
- journal article
- Published by Taylor & Francis in Journal of Cosmetic and Laser Therapy
- Vol. 14 (1) , 2-6
Abstract
Laser hair removal at lower fluences, delivered under certain conditions, may retain the efficacy of high-fluence lasers while improving tolerability. We performed a pilot study comparing the efficacy, safety and tolerability of laser hair removal using traditional settings compared to lower fluences, delivered from a larger handpiece and under vacuum. Fourteen healthy participants underwent 5 axillary hair removal treatments with an 800 nm diode laser at 1-month intervals, with follow-up 1 and 3 months after the 5th treatment. In all patients, one side was treated with standard parameters using a 9 × 9 mm chilled tip and gel, while the contralateral side was treated using a 22 × 35 mm vacuum-assisted handpiece at fluences up to 12 J/cm2. Follow-up assessments were performed after each treatment and at each follow-up visit, and included photography and questionnaires. Eleven participants completed the study and follow-up. All experienced significant hair removal in all treated areas. At the 3-month follow-up visit, the high-fluence and low-fluence treated axillae demonstrated comparable hair reduction. Participants found the lower fluence treatments to be more tolerable. No adverse events were reported. Lower fluence diode laser, delivered under conditions of vacuum and using larger spot sizes, can provide significant hair reduction.Keywords
This publication has 18 references indexed in Scilit:
- Hair structures are effectively altered during 810nm diode laser hair epilation at low fluencesJournal of Dermatological Treatment, 2010
- Hair structures are effectively altered during 810 nm diode laser hair epilation at low fluencesJournal of Dermatological Treatment, 2009
- Histological hair removal study by ruby or alexandrite laser with comparative study on the effects of wavelength and fluenceJournal of Cosmetic and Laser Therapy, 2004
- Comparing 18- Versus 12-mm Spot Size in Hair Removal Using a Gentlease 755-nm Alexandrite LaserDermatologic Surgery, 2004
- Optimizing treatment parameters for hair removal using long-pulsed Nd:YAG-lasersLasers in Medical Science, 2004
- Ruby laser hair removal: Evaluation of long-term efficacy and side effectsLasers in Surgery and Medicine, 2000
- Ruby Laser-Assisted Hair Removal Success in Relation to Anatomic Factors and Melanin Content of Hair FolliclesPlastic and Reconstructive Surgery, 1999
- Ruby Laser-Assisted Hair Removal Success in Relation to Anatomic Factors and Melanin Content of Hair FolliclesPlastic and Reconstructive Surgery, 1999
- Damage to hair follicles by normal-mode ruby laser pulsesJournal of the American Academy of Dermatology, 1996
- Selective Photothermolysis: Precise Microsurgery by Selective Absorption of Pulsed RadiationScience, 1983