A Benchmark Study with Seal Chip ™ Planar Patch-Clamp Technology
Authors:
- Jia XuJXJia Xu
- António GuiaAGAntónio Guia
- David RothwarfDRDavid Rothwarf
- Mingxian HuangMHMingxian Huang
- Khachone SithiphongKSKhachone Sithiphong
- Joe OuangJOJoe Ouang
- Guoliang TaoGTGuoliang Tao
- Xiaobo WangXWXiaobo Wang
- Lei WuLWLei Wu
- 1 October 2003
- journal article
- research article
- Published by SAGE Publications in ASSAY and Drug Development Technologies
- Vol. 1 (5) , 675-684
Abstract
Although conventional patch-clamp methods provide high information content, they are labor-intensive and suffer from low throughput and high overall cost. Several approaches for achieving high throughput electrophysiology are under development, among which microchip-based patch-clamp systems uniquely achieve a higher degree of miniaturization, faster perfusion and mixing, and lower reagent cost without losing information content. The goal of this study was to establish a benchmark for our biochip technology with 52 chips tested sequentially. We demonstrate that our microfabrication and processing technology is sufficiently mature to produce a consistent hole size. We further demonstrate high-quality planar whole-cell patch clamping with >75% overall success rate at achieving gigaohm seals, followed by stable whole-cell access lasting at least 15 min with access resistance (Ra) below 15 MΩ and membrane resistance (Rm) above 200 MΩ. These biochips are ideally suited for high throughput compound screening for ion channel targets.Keywords
This publication has 14 references indexed in Scilit:
- Micromolded PDMS planar electrode allows patch clamp electrical recordings from cellsBiosensors and Bioelectronics, 2002
- Whole Cell Patch Clamp Recording Performed on a Planar Glass ChipBiophysical Journal, 2002
- Ion-channel assay technologies: quo vadis?Drug Discovery Today, 2001
- Bilayer Reconstitution of Voltage-Dependent Ion Channels using a Microfabricated Silicon ChipBiophysical Journal, 2001
- Microstructured glass chip for ion-channel electrophysiologyPhysical Review E, 2001
- A Chip-Based Biosensor for the Functional Analysis of Single Ion Channels2000
- Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patchesPflügers Archiv - European Journal of Physiology, 1981
- Reconstruction of the repolarization process in cardiac Purkinje fibres based on voltage clamp measurements of membrane currentThe Journal of Physiology, 1969
- Reconstitution of Cell Membrane Structure in vitro and its Transformation into an Excitable SystemNature, 1962
- Active Transport of Sodium as the Source of Electric Current in the Short‐circuited Isolated Frog Skin.Acta Physiologica Scandinavica, 1951