Probing Differences in Mass-Transfer Coefficients in Beaker and Stirrer Digestion Systems and the USP Dissolution Apparatus 2 Using Benzoic Acid Tablets
Open Access
Abstract
Measurements of external mass-transfer coefficients for dissolution have been made with benzoic acid tablets with a diameter of 13 mm and approximately 3 mm thick, using two different dissolution systems. One system has been a beaker with a platform for the tablet and either 80 mL or 120 mL of water, with three different types of stirrers, and the other has been a USP dissolution apparatus 2 (paddle) with either 200 mL or 900 mL water. Various stirring speeds have also been used in the different pieces of equipment. The same mass-transfer coefficient may potentially be obtained from the same tablet by adjusting the operating conditions in the two different devices. The ranges of the external mass-transfer coefficients measured in both devices overlapped significantly, with the range being 0.193–4.48 × 10−5 m s−1 in the beaker and stirrer system and 0.222–3.45 × 10−5 m s−1 in the USP dissolution apparatus 2. Dimensional analysis of the results, using Sherwood and Reynolds numbers, shows that the Ranz–Marshall correlation provides a lower bound for estimates of the Sherwood numbers measured experimentally. Calculations of time constants for mass transfer suggest that mass transfer may be a rate-limiting step for dissolution and food digestion under some circumstances. The range of mass-transfer coefficients measured here is representative of other measurements from the literature, and the use of the Ranz–Marshall correlation supports the suggestion that this range of values should be generally expected in most situations.Keywords
This publication has 26 references indexed in Scilit:
- Single droplet drying for optimal spray drying of enzymes and probioticsTrends in Food Science & Technology, 2012
- Dissolution Testing for Generic Drugs: An FDA PerspectiveThe AAPS Journal, 2011
- Mass Transfer and Nutrient Absorption in a Simulated Model of Small IntestineJournal of Food Science, 2010
- Manipulating Digestion with Foods Designed to Change the Physical Characteristics of DigestaCritical Reviews in Food Science and Nutrition, 2010
- Hydrodynamic, mass transfer, and dissolution effects induced by tablet location during dissolution testingJournal of Pharmaceutical Sciences, 2009
- Shear distribution and variability in the USP Apparatus 2 under turbulent conditionsInternational Journal of Pharmaceutics, 2004
- Investigation of Excipient Type and Level on Drug Release from Controlled Release Tablets Containing HPMCPharmaceutical Development and Technology, 2002
- Concentration-dependent diffusivity of benzoic acid in water and its influence on the liquid-solid mass transferThe Canadian Journal of Chemical Engineering, 1986
- Viscosity of liquid water in the range −8 °C to 150 °CJournal of Physical and Chemical Reference Data, 1978
- Explaining solubilization kineticsAIChE Journal, 1976