Abstract
X-ray equipment should be routinely checked for optimal imaging performance and appropriate radiation dose. Recently, the use of diagnostic x-ray equipment with flat panel detectors (FPDs) has increased instead of image intensifier (II) and/or screen film systems. In addition, it is necessary to maintain the performance of FPD systems. Unfortunately, no simple quality control (QC) phantom is available for easy evaluation of FPD image performance. This manuscript suggests a novel simple and inexpensive QC phantom for radiography and fluoroscopy. The authors made a new QC phantom for FPD systems to evaluate the spatial resolution, low-contrast resolution, and dynamic range on single (one-shot) x-ray exposures. The phantom consists of three copper thicknesses (0.5, 1.5, and 3.0 mm), an aluminum stepwedge (0.1–2.7 mm), and piano wire of various diameters (0.08–0.5 mm). They also performed an initial check of the new phantom using a FPD system (fluoroscopic and radiographic images). The new phantom is simple and inexpensive to make. This simple phantom is very useful for QC of FPD systems because a visual evaluation of image performance in three thicknesses of copper (low, intermediate, and high attenuation) is readily available with a single exposure. This simple method for daily checking of FPD systems (radiography and fluoroscopy) using the phantom constitutes an easy way to routinely check image performance and will be useful for QC.Keywords
This publication has 10 references indexed in Scilit:
- RADIATION PROTECTION IN PEDIATRIC INTERVENTIONAL CARDIOLOGY: AN IAEA PILOT PROGRAM IN LATIN AMERICAHealth Physics, 2011
- Radiation Dose of Interventional Radiology System Using a Flat-Panel DetectorAmerican Journal of Roentgenology, 2009
- Radiation Exposure to Patients During Interventional Procedures in 20 Countries: Initial IAEA Project ResultsAmerican Journal of Roentgenology, 2009
- EXPOSURE REDUCTION THROUGH QUALITY ASSURANCE FOR DIAGNOSTIC X-RAY PROCEDURESHealth Physics, 2008
- Radiation dose survey in a paediatric cardiac catheterisation laboratory equipped with flat-panel detectorsRadiation Protection Dosimetry, 2008
- PATIENT RADIATION EXPOSURE MEASUREMENTS DURING INTERVENTIONAL PROCEDURES: A PROSPECTIVE STUDYHealth Physics, 2006
- Relationship Between Fluoroscopic Time, Dose–Area Product, Body Weight, and Maximum Radiation Skin Dose in Cardiac Interventional ProceduresAmerican Journal of Roentgenology, 2006
- Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratoryRadiation Protection Dosimetry, 2004
- Management of Patient Skin Dose in Fluoroscopically Guided Interventional ProceduresJournal of Vascular and Interventional Radiology, 2000
- Relationship between the Pixel Value in Digital Subtraction Angiography and Iodine Concentration: Study in High Iodine Concentration with Original PhantomThe Tohoku Journal of Experimental Medicine, 2000