Exposure Rates of Wrapped and Unwrapped Orbital Implants Following Enucleation
Authors:
- Joanne ShenJSJoanne Shen
- Mark T. DuffyMDMark T. Duffy
- 1 November 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 17 (6) , 431-435
Abstract
To compare the complication rate of porous polyethylene orbital motility implants with solid acrylic implants following enucleation and identify possible risk factors. The authors retrospectively reviewed the charts of a total of 117 consecutive enucleations performed at the University of Illinois at Chicago between March 28, 1994, and May 28, 1999. Data obtained included patient demographics, surgical indication, implant type, attending surgeon, surgical technique, and any reported complications. The primary outcome was presence or absence of implant exposure at the final recorded visit. Of the 117 identified cases, 29 were eliminated due to insufficient follow-up data. Of the 88 remaining cases, 48 patients received porous implants and 40 received solid acrylic implants. Implant exposure developed in four cases. All exposures occurred in unwrapped porous polyethylene implants (n=2) or porous polyethylene implants wrapped in absorbable material (n=2). All exposures occurred in patients younger than 18 years of age, and 75% occurred early after trauma-associated enucleation surgery. The exposure rate of porous polyethylene implants in this study (9%) was found to be comparable to published rates for hydroxyapatite implants. There were no exposures of unwrapped solid acrylic spheres. Unwrapped porous implants in pediatric patients or following trauma-related enucleation may represent an increased risk for postoperative implant exposure. Absorbable wrapping of porous implants may carry the same risk for exposure as no wrapping. Porous implants wrapped in durable material appear to be as safe as solid acrylic spheres.Keywords
This publication has 20 references indexed in Scilit:
- Enucleation: Past, Present, and FutureOphthalmic Plastic & Reconstructive Surgery, 2000
- Exposure of primary orbital implants in postenucleation retinoblastoma patients11The authors have no financial or proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- Porous polyethylene orbital implant in patients with retinoblastoma 11The authors have no proprietary interest in any type of orbital implant discussed in this article.Ophthalmology, 1998
- Complications of Hydroxyapatite Orbital ImplantsOphthalmology, 1997
- Complications of Porous Spherical Orbital ImplantsOphthalmology, 1995
- Coralline Hydroxyapatite Spheres as Secondary Orbital Implants in AnophthalmosOphthalmology, 1995
- Hydroxyapatite Orbital Implant AbscessOphthalmic Plastic & Reconstructive Surgery, 1994
- Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.British Journal of Ophthalmology, 1994
- Animal Model of Porous Polyethylene Orbital ImplantsOphthalmic Plastic & Reconstructive Surgery, 1994
- Bayesian Joint Estimation of Binomial ProportionsJournal of Educational Statistics, 1991