Analysis of measurements from the first Swedish universal neonatal hearing screening program
Author:
- 1 January 2007
- journal article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 46 (11) , 680-685
Abstract
This study analyses results from the first Swedish UNHS program. It includes over 33 000 measurement files from 14 287 children at two maternity wards. The screening program uses a two-stage TEOAE test procedure. A database was created in MedLog after data transformation in Word and Excel. The coverage rate was 99.1%. Bilateral pass rate after retesting was 97.0%. A unilateral pass criterion would have resulted in 1268 fewer children (9.0% of target group) for retesting and 231 fewer children (1.6% of target group) for diagnostic evaluation. When the first test was performed on the day the child was born, the pass rate was 64.8%; the pass rate increased to 89.2% when testing> or =3 days after birth. High coverage rates and pass rates were found to be possible, independent of the number of children born at the maternity ward. Learning curves were observed in the program with improvements distributed over time. Test performance was clearly better when the children were tested day two after birth or later.Keywords
This publication has 20 references indexed in Scilit:
- Characteristics of women giving birth at home in Sweden: A national register studyAmerican Journal of Obstetrics and Gynecology, 2006
- Universal newborn hearing screening follow-up in two Georgia populations: Newborn, mother and system correlatesInternational Journal of Pediatric Otorhinolaryngology, 2006
- Neonatal screening for hearing impairment—The Oman experienceInternational Journal of Pediatric Otorhinolaryngology, 2006
- Ten-year outcome of newborn hearing screening in AustriaInternational Journal of Pediatric Otorhinolaryngology, 2006
- Cribado universal de la hipoacusia congénita en Cantabria: resultados de los dos primeros añosAnales de Pediatría, 2005
- Neonatal hearing screening with transient evoked otoacoustic emissions - retrospective analysis on performance parametersScandinavian Audiology, 2001
- The Rhode Island Hearing Assessment Program: Experience with statewide hearing screening (1993-1996)The Journal of Pediatrics, 1998
- The effects of noise in transient EOAE newborn hearing screeningInternational Journal of Pediatric Otorhinolaryngology, 1994
- Factors Affecting the Interpretation of Transient Evoked Otoacoustic Emission Results in Neonatal Hearing ScreeningSeminars in Hearing, 1993
- An advanced cochlear echo technique suitable for infant screeningBritish Journal of Audiology, 1987