Occupational Chronic Sevoflurane Exposure in the Everyday Reality of the Anesthesia Workplace
Authors:
- Jennifer Herzog-NiesceryJHJennifer Herzog-Niescery
- Nikolaj Matthias BotteckNBNikolaj Matthias Botteck
- Heike VogelsangHVHeike Vogelsang
- Philipp GudePGPhilipp Gude
- Horst BartzHBHorst Bartz
- Thomas Peter WeberTWThomas Peter Weber
- Hans-Martin SeippHSHans-Martin Seipp
- 1 December 2015
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 121 (6) , 1519-1528
Abstract
Nes, depending on the kind of induction for general anesthesia, the used airway device, and the type of airflow system in the operating room. Furthermore, sevoflurane baselines and typical peaks during general anesthesia were determined. METHODS: Measurements were performed with the LumaSense Photoacoustic Gas Monitor. As we detected the gas monitor’s cross-sensitivity reactions between sevoflurane and disinfectants, regression lines for customarily used disinfectants during surgery (Cutasept®, Octeniderm®) and their alcoholic components were initially analyzed. Hospital sevoflurane concentrations were thereafter measured during elective surgery in 119 patients. The amount of inhaled sevoflurane by anesthesiologists was estimated according to mVA = cVA × V × t × ρVA aer. RESULTS: Induction of general anesthesia stopped after tracheal intubation with the patient’s expiratory sevoflurane concentration of 1.5%. Thereby, inhalational inductions (INH) caused higher sevoflurane concentrations than IV inductions (mean [SD]: JOURNAL/asag/04.03/00000539-201512000-00023/math_23MM1/v/2021-01-04T012812Z/r/image-tiff [ppm] INH 2.43 ±1.91 versus IV 0.62 ± 0.33, P < 0.001; mVA [mg] INH 1.95 ± 1.54 versus IV 0.30 ± 0.22, P < 0.001). The use of laryngeal mask airway (LMA™) led to generally higher sevoflurane concentrations in the anesthesiologists’ breathing zones than tracheal tubes ( JOURNAL/asag/04.03/00000539-201512000-00023/math_23MM2/v/2021-01-04T012812Z/r/image-tiff [ppm] tube 0.37 ± 0.16 versus LMA™ 0.79 ± 0.53, P = 0.009; JOURNAL/asag/04.03/00000539-201512000-00023/math_23MM3/v/2021-01-04T012812Z/r/image-tiff [ppm] tube 1.91 ± 0.91 versus LMA™ 2.91 ± 1.81, P = 0.057; mVA [mg] tube 1.47 ± 0.64 versus LMA™ 2.73 ± 1.81, P = 0.019). Sevoflurane concentrations were trended higher during surgery in operating rooms with turbulent flow (TF) air-conditioning systems compared with laminar flow (LF) air-conditioning systems ( JOURNAL/asag/04.03/00000539-201512000-00023/math_23MM4/v/2021-01-04T012812Z/r/image-tiff [ppm] TF 0.29 ± 0.12 versus LF 0.13 ± 0.06, P = 0.012; mVA [mg/h] TF 1.16 ± 0.50 versus LF 0.51 ± 0.25, P = 0.007). CONCLUSIONS: Anesthesiologists are chronically exposed to trace concentrations of sevoflurane during work. Inhalational inductions, LMA™, and TF air-conditioning systems in particular are associated with higher sevoflurane exposure. However, the amount of inhaled sevoflurane per day was lower than expected, perhaps because concentrations in previous measurements could be overestimated (10%–15%) because of the cross-sensitivity reaction....Keywords
This publication has 20 references indexed in Scilit:
- Occupational exposure to sevoflurane during cardiopulmonary bypassPerfusion, 2011
- Exposure to anesthetic gases and congenital anomalies in offspring of female registered nursesAmerican Journal of Industrial Medicine, 2011
- Exposure to anaesthetic trace gases during general anaesthesia: CobraPLA vs. LMA classicActa Anaesthesiologica Scandinavica, 2010
- The Relative Exposure of the Operating Room Staff to Sevoflurane During Intracerebral SurgeryAnesthesia & Analgesia, 2009
- Increased formation of sister chromatid exchanges, but not of micronuclei, in anaesthetists exposed to low levels of sevofluraneAnaesthesia, 2008
- Minimal-flow anaesthesia with controlled ventilation: comparison between laryngeal mask airway and endotracheal tubeEuropean Journal of Anaesthesiology, 2001
- Occupational exposure to sevoflurane, halothane and nitrous oxide during paediatric anaesthesia Waste gas exposure during paediatric anaesthesiaAnaesthesia, 1997
- Reaction of Sevoflurane and Its Degradation Products with Soda LimeAnesthesiology, 1992
- Mutagenicity of Experimental Inhalational Anesthetic AgentsAnesthesiology, 1982
- LAMINAR/LINEAR FLOW SYSTEM OF VENTILATION: Its Application to Medicine and SurgeryThe Lancet, 1970