An evaluation of silicone‐hydrogel lenses worn on a daily wear basis
Authors:
Open Access
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 89 (1) , 18-25
Abstract
To examine the clinical performance of two brands of silicone-hydrogel lenses when worn on a daily wear basis. Fifty-six subjects with no ocular disease were enrolled at multiple sites in Australasia. Contact lenses made from galyfilcon A or lotrafilcon A were randomly assigned to each eye of the subject and the lenses were worn on a daily wear basis for a period of two weeks. Subjects did not know the identity of the lenses they wore. Clinical data and patient responses to a questionnaire were gathered at an initial visit and after two weeks of wear. For both lenses, the degree of limbal hyperaemia and bulbar conjunctival hyperaemia decreased significantly over the two-week wearing period. The eyes wearing galyfilcon A lenses showed an increase in conjunctival staining compared to the baseline measures. On average, galyfilcon A lenses decentred more and moved less than the lotrafilcon A lenses. The lotrafilcon A lenses showed a greater loss of wettability, as judged by practitioner grading, than the galyfilcon A lenses over the two-week period. The subjective responses showed strong preference for the galyfilcon A lens across 26 of 27 questions relating to comfort, vision, handling, preference and other subjective outcomes. The results show that different silicone-hydrogel lenses have different performance characteristics on the eye, when worn on a daily wear basis. Striving for high oxygen transmissibility at the expense of other properties may lead to a range of undesirable performance characteristics.Keywords
This publication has 12 references indexed in Scilit:
- Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moietiesBiomaterials, 2004
- Use of silicone hydrogel contact lenses by Australian optometristsClinical and Experimental Optometry, 2004
- Local oxygen transmissibility of disposable contact lensesContact Lens and Anterior Eye, 2003
- Effects of Eyelid Closure and Disposable and Silicone Hydrogel Extended Contact Lens Wear on Rabbit Corneal Epithelial ProliferationInvestigative Ophthalmology & Visual Science, 2003
- A 1-year prospective clinical trial of balafilcon a (purevision) silicone-hydrogel contact lenses used on a 30-day continuous wear scheduleOphthalmology, 2002
- Comparative clinical performance of two silicone hydrogel contact lenses for continuous wearClinical and Experimental Optometry, 2002
- Soft contact lens polymers: an evolutionBiomaterials, 2001
- Vascular Response to Extended Wear of Hydrogel Lenses with High and Low Oxygen PermeabilityOptometry and Vision Science, 2001
- A Model of Oxygen Flux Through Contact LensesCornea, 2001
- Grading scales for contact lens complicationsOphthalmic and Physiological Optics, 1998