Temporary pacemaker implantation via median cubital vein: A simple safe and effective technique
Open Access
- 31 July 2023
- journal article
- research article
- Published by Wiley in Clinical Cardiology
- Vol. 46 (10) , 1268-1275
Abstract
Background: Temporary cardiac pacemaker implantation (PM) via the femoral and subclavian veins is widely used in clinics to treat patients with severe bradycardia or tachycardia, but it is technically challenging and potentially associated with various complications.Hypothesis: This study investigated the feasibility and safety of a novel method of PM implantation via the median cubital vein.Methods: A total of 279 patients of the First Affiliated Hospital of Xiamen University between March 2020 and December 2021 who required no‐emergency PM implantation were enrolled. The patients were divided into three groups based on the temporary PM implantation routes: F‐control (n = 107), via the femoral vein; S‐control (n = 67), via the subclavian vein, and N‐group (n = 105), via the median cubital vein. The sheath placement time (SPT), electrode placement time (EPT), electrode arrival rate (EAR), rate of sensing and pacing (RSP), radiation quantity (RD), electrode dislocation rate (EDR) and average electrode retention time (AERT) were recorded and evaluated. In addition, the Hamilton Anxiety Scale (HAMA) and Self‐Rating Depression Scale (SDS) were used to evaluate the comfort levels of patients in the three groups.Results: There were no significant differences between the groups with regard to age, EAR, RSP, EPT, RD, and AERT (p > 0.05). However, the N‐group had significantly lower SPT than the F‐control and S‐control groups (67.0 ± 22.0 s vs. 321.7 ± 122.2 s and 307.3 ± 128.5 s, p = 0.000). Additionally, the F‐control had significantly higher EDR than the S‐control group and the N‐group (11 (10.3%) vs. 2 (3.0%) and 3 (2.9%), p = 0.036). Besides, comparison of the HAMA and SDS scores before and after PM implantation showed significant differences in the S‐control group (p = 0.010) and the N‐group (p = 0.000).Conclusions: Temporary PM implantation via the median cubital vein is safe, effective, and less time‐consuming.Keywords
Funding Information
- National Natural Science Foundation of China (82170266, 81870183)
This publication has 17 references indexed in Scilit:
- Sinus Node and Atrial ArrhythmiasCirculation, 2016
- Hamilton Rating Scale for Anxiety (HAM-A)Occupational Medicine, 2015
- Pacemaker insertion2015
- Anxiety rating scales in Parkinson's disease: A validation study of the Hamilton anxiety rating scale, the Beck anxiety inventory, and the hospital anxiety and depression scaleMovement Disorders, 2011
- Åke SenningClinical Cardiology, 2009
- Pacemaker therapies in cardiology.2007
- A Review of Temporary Cardiac Pacing Wires2007
- Complications of Femoral and Subclavian Venous Catheterization in Critically Ill PatientsA Randomized Controlled TrialJAMA, 2001
- Reliability and Validity of the Hamilton Anxiety Rating Scale in an Adolescent SampleJournal of the American Academy of Child & Adolescent Psychiatry, 1994
- A Self-Rating Depression ScaleArchives of General Psychiatry, 1965