Prevention of Knot Slippage with the Use of Cyanoacrylate Glue: A Mechanical Study
Authors:
Open Access
- 1 April 2013
- journal article
- research article
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 21 (1) , 65-67
Abstract
To assess the effect of cyanoacrylate glue on knot slippage and strength in vitro. Ethibond 3/0 was tested using a tensile tester. A single drop of cyanoacrylate glue was applied to the knots. Seven knot configurations (10 samples each) were tested: (1) a surgeon's knot (S) plus 4 square throws (+4) without glue (control group), (2) S plus one square throw (+1) without glue, (3) S+1 with glue, (4) S with glue, (5) S+1 wet post-tie without glue, (6) S+1 wet pre-tie without glue, and (7) S+1 wet pre-tie with glue. Wet sutures were immersed in normal saline for 24 hours prior to knot tying. Wet pre- and post-tie sutures were immersed for one minute prior to knot tying and tensile testing, respectively. Outcome measures were the mode of failure (knot slippage or suture snapping) and the ultimate tensile strength. All knots without glue failed owing to knot slippage, except for the controls, whereas all knots with glue failed owing to suture snapping. The ultimate tensile strength was significantly higher in knots with glue and controls than in knots without glue. The ultimate tensile strength did not differ significantly between S+4 without glue and S with glue (p=0.48), indicating that glue could reinforce knots and reduce the number of throws needed. Wet suture is protective against failure (p<0.01). Cyanocrylate glue may have clinical applications for flexor tendon repairs for which a reduced knot size is advantageous.Keywords
This publication has 12 references indexed in Scilit:
- Security of Knots Tied with Ethibond, Fiberwire, Orthocord, or UltrabraidThe American Journal of Sports Medicine, 2008
- Optimum surgical suture material and methods to obtain high tensile strength at knots: problems of conventional knots and the reinforcement effect of adhesive agentJournal of Orthopaedic Science, 2006
- Strength and Knot Security of Braided Polyester and Caprolactone/Glycolide SutureFoot & Ankle International, 2004
- Comparison of Postoperative Early Active Mobilization and Immobilization in Vivo Utilising a Four-Strand Flexor Tendon RepairJournal of Hand Surgery (European Volume), 2001
- In vitro biomechanical analysis of suture methods for flexor tendon repairJournal of Orthopaedic Research, 1993
- Elongation of the repair configuration following flexor tendon repairThe Journal of Hand Surgery, 1983
- Mechanical Properties of Suture MaterialsAnnals of Surgery, 1981
- Mechanical performance of surgical suturesThe American Journal of Surgery, 1975
- Knot security and synthetic suture materialsThe American Journal of Surgery, 1974
- SURGICAL KNOTSAnnals of Surgery, 1938