Electron paramagnetic resonance radiation dose assessment in fingernails of the victim exposed to high dose as result of an accident
- 24 June 2014
- journal article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 53 (4) , 755-762
Abstract
In this paper, we report results of radiation dose measurements in fingernails of a worker who sustained a radiation injury to his right thumb while using 130 kVp X-ray for nondestructive testing. Clinically estimated absorbed dose was about 20–25 Gy. Electron paramagnetic resonance (EPR) dose assessment was independently carried out by two laboratories, the Naval Dosimetry Center (NDC) and French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). The laboratories used different equipments and protocols to estimate doses in the same fingernail samples. NDC used an X-band transportable EPR spectrometer, e-scan produced by Bruker BioSpin, and a universal dose calibration curve. In contrast, IRSN used a more sensitive Q-band stationary spectrometer (EMXplus) with a new approach for the dose assessment (dose saturation method), derived by additional dose irradiation to known doses. The protocol used by NDC is significantly faster than that used by IRSN, nondestructive, and could be done in field conditions, but it is probably less accurate and requires more sample for the measurements. The IRSN protocol, on the other hand, potentially is more accurate and requires very small amount of sample but requires more time and labor. In both EPR laboratories, the intense radiation-induced signal was measured in the accidentally irradiated fingernails and the resulting dose assessments were different. The dose on the fingernails from the right thumb was estimated as 14 ± 3 Gy at NDC and as 19 ± 6 Gy at IRSN. Both EPR dose assessments are given in terms of tissue kerma. This paper discusses the experience gained by using EPR for dose assessment in fingernails with a stationary spectrometer versus a portable one, the reasons for the observed discrepancies in dose, and potential advantages and disadvantages of each approach for EPR measurements in fingernails.Keywords
This publication has 18 references indexed in Scilit:
- Advances towards using finger/toenail dosimetry to triage a large population after potential exposure to ionizing radiationRadiation Measurements, 2011
- DOSIMETRY BASED ON EPR SPECTRAL ANALYSIS OF FINGERNAIL CLIPPINGSHealth Physics, 2010
- EX VIVO ANALYSIS OF IRRADIATED FINGERNAILS: CHEMICAL YIELDS AND PROPERTIES OF RADIATION-INDUCED AND MECHANICALLY-INDUCED RADICALSHealth Physics, 2010
- FINGERNAIL DOSIMETRY: CURRENT STATUS AND PERSPECTIVESHealth Physics, 2010
- Electron paramagnetic resonance radiation dosimetry in fingernailsRadiation Measurements, 2009
- Protocol for emergency EPR dosimetry in fingernailsRadiation Measurements, 2007
- EPR dosimetry in chemically treated fingernailsRadiation Measurements, 2007
- Dose estimation by ESR spectroscopy at a fatal radiation accidentInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1989
- Evaluation of ESR as a radiation accident dosimetry techniqueInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1989
- Sulphur radicals formed by cutting α-keratinNature, 1987