Acetabular Bone Preservation in H1 Ceramic Hip Resurfacing: A Comparison With A Conventional Metal‐on‐Metal Hip Resurfacing
Authors:
Open Access
- 7 May 2026
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (5) , e70221
Abstract
This study compared the volume of acetabular bone resection between an anatomically designed cementless ceramic‐on‐ceramic hip resurfacing arthroplasty (H1HR) and metal‐on‐metal hip resurfacing (Birmingham Hip Resurfacing; BHR). We hypothesized that the anatomical design of the H1 cup would reduce the need for medialization to avoid rim overhang, thereby preserving acetabular bone stock. A retrospective three‐dimensional simulation study was performed in 12 hips with osteoarthritis and femoral head size ≥ 48 mm. H1HR and BHR were virtually implanted using 3D planning software to minimize the risk of groin pain. The primary outcome was the volume of acetabular bone resection. Secondary outcomes included the position of the cup relative to the native hip centre and the cup non‐coverage ratio. H1 cups required a mean volume of acetabular bone resection of 11 cm 3 , while BHR cups required 17 cm 3 . This 35% reduction was statistically significant. H1 cups had less medialization (−1 mm vs. −6 mm), superior displacement (−1 mm vs. −2 mm), and posterior displacement (−1 mm vs. −3 mm). The mean cup non‐coverage ratio was not significantly different (10% vs. 8%). The anatomically designed H1HR achieved a significant 35% reduction in acetabular bone resection compared with BHR. This substantial volume of bone preservation was primarily attributed to the design enabling cup placement with minimal medialization, without increasing the cup non‐coverage ratio. Although further validation in cadaveric or postoperative imaging studies is needed, H1 may be a promising option for bone preservation, particularly for young, active patients who might require future revision surgery.Keywords
This publication has 30 references indexed in Scilit:
- The Results of a Press-Fit-Only Technique for Acetabular Fixation in Hip DysplasiaThe Journal of Arthroplasty, 2011
- Comparison of Bone Removed During Total Hip Arthroplasty With a Resurfacing or Conventional Femoral Component: A Cadaveric StudyThe Journal of Arthroplasty, 2010
- Comparison of Acetabular Reamings during Hip Resurfacing versus Uncemented Total Hip ArthroplastyJournal of Orthopaedic Surgery, 2009
- Does Hip Resurfacing Require Larger Acetabular Cups Than Conventional THA?Clinical Orthopaedics and Related Research, 2009
- Factors affecting acetabular bone loss during primary hip arthroplasty – A quantitative analysis using computer simulationClinical Biomechanics, 2008
- Birmingham hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2008
- A randomised study comparing resection of acetabular bone at resurfacing and total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Removal of acetabular bone in resurfacing arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2006
- Dislocations after total hip-replacement arthroplasties.Journal of Bone and Joint Surgery, 1978
- A STUDY TO DETERMINE THE ANGLE OF ANTEVERSION OF THE NECK OF THE FEMURJournal of Bone and Joint Surgery, 1948