Effect of wind in the design of reinforced concrete buildings
Authors:
- L.S. TapajósLTL.S. Tapajós
- J. A .T. FerreiraJFJ. A .T. Ferreira
- A. F. Lima NetoANA. F. Lima Neto
- M. R. TeixeiraMTM. R. Teixeira
- M. P. FerreiraMFM. P. Ferreira
Open Access
- 1 December 2016
- journal article
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 9 (6) , 883-910
Abstract
This paper presents the results from a parametric study carried in order to quantify how far errors in the design stage related to the consideration of the wind action may put at risk the response and safety of reinforced concrete buildings. Using an architectural model as reference and varying the number of floors of the building, the structural safety was evaluated as a function of the wind action intensity. Results showed that even for low-rise buildings, with 10 floors, ignoring the wind action can significantly jeopardize their behaviour and safety. Yet, for slenderer buildings, up to 30 floors, it can lead to catastrophic results, as the ruin of the structure by progressive collapse.Keywords
This publication has 14 references indexed in Scilit:
- Reliability study and simulation of the progressive collapse of Roissy Charles de Gaulle AirportCase Studies in Engineering Failure Analysis, 2015
- Cantilever steel post damaged by windCase Studies in Engineering Failure Analysis, 2014
- Another Look at the Collapse of Skyline Plaza at Bailey’s Crossroads, VirginiaJournal of Performance of Constructed Facilities, 2013
- Failure analysis on collapsed towers of overhead electrical lines in the region Münsterland (Germany) 2005Engineering Failure Analysis, 2011
- An improved tie force method for progressive collapse resistance design of reinforced concrete frame structuresEngineering Structures, 2011
- The progressive failure of 15 balconies and the engineering techniques for their reconstructionEngineering Failure Analysis, 2011
- Investigation of transmission line tower failuresEngineering Failure Analysis, 2010
- An investigation on failed or damaged reinforced concrete structures under their own-weight in TurkeyEngineering Failure Analysis, 2007
- Collapse of 2000 Commonwealth Avenue: Punching Shear Case StudyJournal of Performance of Constructed Facilities, 2004
- Lessons from the Sampoong department store collapseCement and Concrete Composites, 2002