Study on the dynamic response characteristics of non-uniform ice-shedding from ice-covered transmission lines
Authors:
Open Access
- 10 July 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 12, 1832735
Abstract
Ice shedding from transmission lines may lead to severe hazards, such as inter-phase short circuits, conductor strand breakage, and even tower collapse. Understanding the dynamic response characteristics during ice-shedding is crucial for ensuring operational and structural safety. In this study, we used the ANSYS finite-element simulation platform to establish a five-span continuous overhead transmission-line model incorporating both conductor and insulator strings to explore the dynamic responses of and factors influencing non-uniform ice-shedding. First, we developed a finite-element model of the transmission line and defined simulation methods for ice accretion and shedding loads. Then, we analyzed the dynamic responses of lines with uniform ice coverage under three non-uniform ice-shedding conditions: left-side shedding, mid-span shedding, and double-end shedding. The results indicate that mid-span shedding leads to the highest ice-shedding jump height and unbalanced tension; the ice cover may shed during temperature fluctuations caused by sunlight or external disturbances and other factors. Finally, we discuss the influences of the ice-shedding condition, span length, and elevation difference between the suspension points of the transmission line on the dynamic responses. Mid-span shedding was found to be the highest-risk scenario, with both the ice-shedding jump height and unbalanced tension in this condition being significantly higher than in the other two scenarios; span length had the most significant impact on the dynamic response of the line, while elevation differences were noted to exacerbate the unbalanced tension; finally, mid-span shedding under centrally concentrated ice accumulation produced the most intense dynamic response.Keywords
This publication has 4 references indexed in Scilit:
- Dynamic Response Characteristics of Ice-Shedding on Multi-Span Transmission Lines Under Non-Uniform Icing ConditionsIndustrial Construction, 2025
- Vibration of Bundled Conductors Following Ice SheddingIEEE Transactions on Power Delivery, 2008
- Dynamical analysis of transmission line cables. Part 2—damping estimationMechanical Systems and Signal Processing, 2004
- Simulation of ice-shedding on electrical transmission lines using adinaComputers & Structures, 1993